![](/images/backgrounds/272913/272913-5240x1.png)
AE00515
Generator won’t produce power
•Safety device (AC protector) to "Reset"····Press the AC protector to “Set”.
A ENGINE DOES NOT START
BTurn the engine switch to “ON”, then turn
the engine switch to “START”. And check if the starter motor cranks.
C Cranks | D Does not crank |
F Turn the engine switch to “START”, and check if the oil warning light comes on.
G Does not come on H Comes on
LTurn the engine switch to “START” and check the spark plug for spark strength. (See “WARNING”).
w
9To prevent FIRE HAZARDS be sure fuel is not present in the spark plug area.
9To prevent FIRE HAZARDS be sure to place the spark plug as far way as possible from the spark plug hole and car- buretor area.
9To prevent ELECTRIC SHOCK do not hold spark plug lead with hand while testing.
M Engine does not start. | N Engine starts. |
RCheck the following
9 Fuel cock clogging
9 Air cleaner element clogging.
S | Clogged | U | Clean or Replace; Consult a |
| Yamaha dealer. | ||
|
|
| |
T | OK | V | Consult a Yamaha dealer. |
– 35 –