PgmChng (Program Change)

Set to enable or disable reception of a Program Change message coming in. With this parameter set to “on,” the instrument can receive a Program Change massage coming in, and it can also send a Program Change out to an external MIDI device when you select a Voice or Performance (using a [PROGRAM/PART] key, etc.) on its front panel.

Settings: off (disable), on (enable)

Control

Set the MIDI transmit/receive parameters controlling the Sustain parameter of the QED EG.

Settings: mode1, mode2 mode1:

Messages are received as Parameter Change messages.

mode2:

Messages are receives as Control Change messages.

MIDI Other

Set other MIDI parameters.

 

 

 

 

 

 

 

MIDI Other)

ThruPort

Sync

SeqCtrl

￿

 

Sys

1

int

on

 

 

 

 

 

 

 

ThruPort

You can connect your synthesizer to a computer via a dedicated serial cable on the TO HOST connector. In which case, MIDI messages received via the TO HOST connector can be passed through the MIDI OUT connector of the synthesizer. Set the port number here.

Settings: 1 ~ 8

Sync

To synchronize playback with an external MIDI device, you can use either the synthesizer’s internal clock (int) or MIDI clock signals from the external device (midi).

Select “int” if you are using the synthesizer as the master, or if you have no other MIDI devices connected to it. Select “MIDI” when slaving your synthesizer to another MIDI Clock source connected to the MIDI IN connector.

Settings: MIDI, int (internal)

SeqCtrl (Sequencer Control)

Select whether or not to transmit/receive Song Start, Stop and Continue messages via MIDI. This also switches the transmission of MIDI Clock messages on and off.

Settings: off, on

MIDI GM/XG Receive (if a Multi-Part Plug-in Board has been installed)

Set GM On and XG Reset Receive parameters. This screen is only available if a Multi-Part XG Plug-in Board has been installed.

 

 

 

 

 

 

MIDI GM/XG Receive)

Sw

InternalPart

￿

 

Sys

on

layer-part

 

 

 

 

 

 

Sw (Receive Switch)

Select whether or not to receive GM On and XG Reset messages. The XG Plug-in Board will receive GM On and XG Reset messages if you set this to “on.”

Settings: off, on

InternalPart

The sound for each of the synthesizer’s Parts can be output in the following three ways. when a GM On/XG Reset message is received. Whichever setting you choose, the Parts of the XG Plug-in Board will always be output.

Settings: all part:

All Parts of the synthesizer and the Plug-in Board will be output when MIDI messages are received.

layer part:

Parts which have their Layer Switch parameters set to “on” and all XG Plug-in Board Parts will be output when MIDI messages are received.

all off:

No Parts of the synthesizer will be output but all XG Plug- in Board Parts will be output when MIDI messages are received.

By default the Sw parameter is set to “on” and the InternalPart parameter is set to “all off.” If you play a song file containing a GM On message, the XG Plug-in Board will be used to play back the song.

M.EQ (Voice Master Equalizer)

You can assign any of five different Equalizer bands in Voice Mode. The following five screens are available.

M.EQ Low

M.EQ LowMid (Low-Middle)

M.EQ Mid (Middle)

M.EQ HighMid (High-Middle)

M.EQ High

Q (Frequency Characteristic)

Gain

0

Freq (Frequency)

Utility Mode

131