E
EMU01363
ENGINE FAILS TO OPERATE
If the engine stops unexpectedly, or if the engine does not start, you may attempt to use the following emergency circuit proce- dure. Before using this procedure, be sure to check the “TROUBLESHOOTING” section to eliminate causes such as low fuel or over- heating.
CAUTION:
●This emergency circuit should only be used to return to the nearest harbor for repairs in an emergency. Do not use it again without getting repairs.
●When using the emergency circuit the engine control systems will not make the proper adjustments for operating conditions. Operate only at low speed (less than
To start the engine
1)Adjust the trim so that the engine is ver- tical.
2)Remove the top cowling and locate the yellow wire in the harness.
3)Disconnect the connector for the yellow wire. (The control circuit for the CDI unit will be connected directly.)
4)Install the top cowling.
5)Start the engine using the procedures under “STARTING THE ENGINE.”
1Yellow cord