122 Chapter 10—Control Room Monitoring
DM1000 Version 2—Owner’s Manual
3To solo and monitor Input Channels, press the corresponding LAYER button
to select a Layer that contains the desired channels, then press the channel
[SOLO] buttons.
The channel [SOLO] button indicators and the MONITOR [SOLO] indicator light up.
Only the soloed Input Channel signals are fed to the Control Room Monitor outputs.
4To solo and monitor Output Channels, press the LAYER [MASTER] button,
then press the channel [SOLO] buttons.
Input and Output Channels (Aux Out 1–8, Bus Out 1–8) cannot be solo-monitored simul-
taneously. For example, if you solo an Input Channel, then solo an Output Channel, the
first solo channel is temporarily cancelled.
If you solo an Output Channel first, then solo an Input Channel, canceling the Input Chan-
nel’s solo will activate the Output Channel’s solo.
5You can unsolo all soloed channels by pressing all illuminated channel
[SOLO] buttons.
The button indicators turn off. You can also unsolo all soloed channels by pressing the
MONITOR [CLEAR] button.
Using the Control Room Monitor
1Connect a monitoring system to the outputs (by default, OMNI OUT 11&12)
to which the Control Room Monitor signal is patched.
To monitor the signal via headphones, connect headphones to the PHONES jack.
2Press the MONITOR [DISPLAY] button repeatedly until the Monitor | C-R/TB
page appears.
A2TR DIN FLIP
This parameter enables you to specify the signal source that will be monitored when you
press the MONITOR [2TR D1] or [2TR D2] button.
•2TR D1 & OMNI 1/2... These buttons select the 2TR IN DIGITAL 1 and OMNI IN 1/2
inputs respectively as the signal source that will be monitored
when you press the [2TR D1] button.
•2TR D2 & OMNI 3/4... These buttons select the 2TR IN DIGITAL 2 and OMNI IN 3/4
inputs respectively as the signal source that will be monitored
when you press the [2TR D2] button.
Tip: If the SEL MODE parameter is set to Mix Solo on the Monitor | Solo page, you can solo
multiple Input Channels simultaneously.
3
4
2
1