142 Chapter 11—Surround Functions
DM1000 Version 2—Owner’s Manual
MONITOR ALIGNMENT
You can adjust the Attenuator and Delay for each Surround Monitor Channel. This func-
tion is primarily used to correct the level difference and delay time among speakers.
Move the cursor to the ATT or DLY parameter in the MONITOR FLOW section. The
MONITOR ALIGNMENT diagram is displayed in the area below the section.
Move the cursor to the ATT or DLY parameter box and edit the Attenuator or Delay value.
The Attenuator parameters can be set to – dB or from –12.0 dB to +12.0 dB in 0.1 dB steps.
The Delay parameters can be set from 0.00 to 30.0 msec in 0.02 msec steps.
Setting the Monitoring Level of the Sound System
1Adjust the monitoring levels using the MONITOR [MONITOR LEVEL] control.
All channel monitoring levels change simultaneously.
2 Press the MONITOR [DISPLAY] button repeatedly until the Monitor | Sur-
round page appears.
This page enables you to solo or mute monitoring channels, store the [MONITOR LEVEL]
control setting, and select the monitoring source.
Note:
These parameter settings are effective only on the monitoring signals, not on normal Bus
Out signals.
•If you set Surround mode to 6.1 and Monitor Matrix mode to 6.1 for monitoring, you must
also make the settings described above.
Tip: You can store these settings in the Surround Monitor library. See page 186 for more infor-
mation.
2
3
1