

Thank you for selecting the ZOOM 504 (hereafter simply called the "504").
Please take the time to read this manual carefully so you can get the most out of your 504 and ensure optimum performance and reliability.
Retain this manual for future reference.
ZOOM CORPORATION
NOAH Bldg.,
PHONE:
Printed in Japan
1
Major Features
•New type of compact
•Suitable for use with an acoustic guitar or an electric guitar. Use the dedicated effects for acoustic guitar, or make an electric guitar sound like an acoustic guitar with the
•Unique AIR effect imitates the sound as picked up by a microphone. Reverb and chorus effects help to create a spacious feeling. Enjoy
•Feedback suppressor automatically detects and attenuates problem frequencies. This makes the 504 useful not only for line recording but also on stage.
•Two input jacks with different sensitivity allow optimum matching to any type of guitar, from acoustic guitars with magnetic pickups to electric guitars with humbucking type pickups.
•You can switch between 24 patches to store diverse settings based on your preference.
•Integrated
•Dual power supply design allows the unit to be powered from a 9V alkaline battery (6LR61) or an AC adapter.
2
Safety Precautions
USAGE AND SAFETY PRECAUTIONS
In this manual, symbols are used to highlight warnings and cautions for you to read so that accidents can be prevented. The meanings of these symbols are as follows:
This symbol indicates explanations about extremely dangerous issues. If users ignore this symbol and handle the device incorrectly, serious injury or death could
Warning result.
This symbol indicates explanations about dangerous issues. If users ignore this symbol and handle the device the wrong way, bodily injury and damage to the
Caution equipment could result.
Please observe the following safety tips and precautions to ensure
Usage precautions
Electrical interference
For safety considerations, the 504 has been designed to provide maximum protection against the emission of electromagnetic radiation from inside the device, and from external interference.However, equipment that is very susceptible to interference or that emits powerful electromagnetic waves should not be placed near the 504, as the possibility of interference cannot be ruled out entirely.
Whatever the type of digital control device, the 504 included, electromagnetic damage can cause malfunctioning and corrupt or destroy data. Since this is an
About power
Warning Since power consumption of this unit is fairly high, we recommend the use of an AC adapter whenever possible. When powering the unit from a battery, use only an alkaline type.
AC adapter operation
•Be sure to use only an AC adapter which supplies 9 V DC, 300 mA and is equipped with a "center minus" plug (Zoom
•Connect the AC adapter only to an AC outlet that supplies the rated voltage required by the adapter.
•When disconnecting the AC adapter from the AC outlet, always grasp the adapter itself and do not pull the cable.
•If the unit is not to be used for a long time, disconnect the AC adapter from the outlet.
Battery operation
•Use only a 9 V (alkaline) battery (6LR61).
•The 504 cannot be used for recharging.
Pay close attention to the labelling of the battery to make sure you choose the correct type.
•If the 504 is not to be used for an extended period of time, remove the battery from the unit.
•If battery leakage has occurred, wipe the battery compartment and the battery terminals carefully to remove all remnants of battery fluid.
•While using the unit, the battery compartment cover should be closed.
Environment
Caution Avoid using your 504 in environments where it will be exposed to:
•Extreme temperature
•High humidity or moisture
•Excessive dust or sand
•Excessive vibration or shock
Cleaning
Use a soft, dry cloth to clean the 504. If necessary, slightly moisten the cloth. Do not use abrasive cleanser, wax, or solvents (such as paint thinner or cleaning alcohol), since these may dull the finish or damage the surface.
Connecting cables and input and output jacks
You should always turn off the power to the 504 and all other equipment before connecting or disconnecting any cables. Also make sure to disconnect all cables and the AC adapter before moving the 504.
Handling
Caution • The 504 is a precision instrument. Except for the foot switches, do not push other parts with your feet or subject them to strong force.
•Take care that no foreign objects (coins or pins etc.) or liquids enter the unit.
•Be sure to turn the power to all equipment off before making connections.
•Before moving the unit, turn the power off and disconnect all cables and the AC adapter.
Alterations
Caution Never open the case of the 504 or attempt to modify the product in any way since this can result in damage to the unit.