There are three possible hookup errors: 1) the fault is greater than 20 MΩ, 2) the Red/Green strap is bad, 3) the Red/Yellow strap is bad.

The screen will show the combination of errors that has been detected. Correct the errors and press the [Enter] key to repeat the hookup test.

If no errors in the hook-up are detected, the 965DSP-B will go directly from the hook-up screen to the following results screen.

If the Yield Sign shows beside the results, this indicates a possible inaccuracy in the results (due to noise or other line conditions).

Press [Tab] to show readings in Ohms instead of distance. Press [Enter] to repeat the fault locate using the same Distance to Strap. Press [Setup] to go to the RFL setup screen.