Memory Management | Error: Bus | Possible | software | error. | If | ||
error that occurs while accessing | problem | persists, | check | or | |||
the “other than protected” RAM. | replace CPU/Memory CP. A | ||||||
A warm start is logged after this | warm start or retranslation of the | ||||||
error . |
|
|
| system could be a possible fix for | |||
|
|
|
| this problem. |
|
| |
|
| ||||||
Memory ROM Checksum Error: | If this problem persists, replace | ||||||
Memory has failed the ROM test. | CPU/Memory CP. |
|
| ||||
|
| ||||||
Message Corruption: (Other than | If consistent error for particular | ||||||
CPU/Memory) | port CP, check TDM bus drivers | ||||||
message checksum error. |
| on the CP. If error is associated | |||||
|
|
|
| with many CPs, drivers on CPU | |||
|
|
|
| may be bad. Also check 1/O | |||
|
|
|
| cables and TDM bus terminator. | |||
|
| ||||||
Message From | Translate the CP and its port, or | ||||||
Port: Untranslated port CP sent | remove the CP from system. |
| |||||
an |
|
|
|
|
|
| |
|
| ||||||
No External Release On PBX | Check associated trunk (see | ||||||
Disconnect: | CO did | not release | Figure | ||||
within | log when trunk release occurs | ||||||
ground start trunk after System 25 | belatedly. |
|
| ||||
disconnected. Message | s e n t |
|
|
|
| ||
every |
|
|
|
| |||
|
|
|
| ||||
N o F r e e | Buffer: | (STARLAN | If the reset is not successful, | ||||
Interface CP) This error resets the | reseat board. If the reseat fails, | ||||||
C P . |
|
|
| replace CP. |
|
| |
|
| ||||||
No Loop Current On Incoming | Swap CP with similar CP. If | ||||||
Call: CP does not | detect | dc | problem | follows the boards, | |||
current on | answered incoming | replace CP. If problem persists, | |||||
call. Call will drop. |
|
| test the trunk per Figure |
| |||
|
|
|
|
|
|
|
|