CV7 Touch Panel Accessories

There is one LED indicator on the front of each battery slot that indicates the status of that slot. The blink patterns for these LEDs are described in the following table:

Off:

No battery detected.

Green Flashing: Fast charging.

Green Solid:

Fully charged.

Yellow Flashing: Recalibration in process.

Yellow/Green: Recalibration complete.

Yellow Solid: Standby (waiting for other battery to charge).

Red Flash: Error (problem with either the battery connection to the internal slot, or with the battery itself).

Charging the NXT-BP batteries using the NXT-CHG

1.Review the Checking the NXT-BP charge section on page 23 to confirm the percentage of charge remaining on the batteries.

2.Provide power to the charger (as outlined in the Powering the NXT-CHGsection on page 26).

3.Align the battery connector with the corresponding charge slot.

4.Firmly insert the battery into the desired slot until the battery is both securely located within the slot and there is activity from the corresponding Slot LED. Refer to the Reading the NXT- CHG LED Indicator section on page 26 section for LED information.

Recalibrating the batteries

The recalibration process increases the accuracy of the battery charge level. Recalibration of the batteries is only done upon a user request from the Modero on-screen Battery Base page.

Recalibration can only be done within Slot 1 on the NXT-CHG.

1.Place the selected battery securely into Slot 1 (left slot) until there is activity on the Slot 1 LED.

2.Push the Recalibration pushbutton (located between the two slots) to initiate recalibration in the left bay only.