DS-RPC OWNER’S MANUAL

DETAILED OPERATION AND CONFIGURATION

__________________________________________________________________________________________

Modem to Modem Xon/Xoff Flow Control is ....Disabled

Enable? (Y/N, CR for no change):

 

Type “Y” for yes followed by <cr> if you

 

want to enable Xon/Xoff. Type “N“ for no

 

followed by <cr> if you want to disable

 

Xon/Xoff. Type <cr> for no change. The

 

DS71-MD2 stores the change in non-volatile

 

memory and returns to the Local Modem

 

Setup menu.

 

Connectivity

Configure the amount of connectivity (5 to

Timeout

255 minutes) before the modem

 

automatically disconnects. Entering a time

 

of 0 disables Connectivity Timeout. The

 

timer starts when the modem answers (DCD

 

high). The modem will disconnect,

 

regardless of activity, when time runs out.

 

Default Connectivity Timeout is 60

 

minutes.

 

 

Select #3, “Connectivity Timeout,” from the

 

Local Modem Setup menu, followed by

 

<cr>. The DS71-MD2 displays the current

 

setting and asks if you want to change:

 

Modem Connectivity Time-out is

60 minutes

 

Change It? (Y/N) :

 

Type “Y“ for yes followed by <cr>. The

DS71-MD2 responds:

Enter Connectivity Time-out (5 to 255, 0 = Disabled)

or press ENTER for no change

:

Enter the number of connectivity minutes (5 to 255) or enter 0 to disable. The DS71- MD2 displays the new setting and asks if you want to change. If there are no further changes, type <cr>. The DS71-MD2 stores changes in non-volatile memory and returns to the Local Modem Setup menu.

47

Page 55
Image 55
Bay Technical Associates DS2-RPC, DS4-RPC, DS73, DS2-RPC DS4-RPC Default Connectivity Timeout is, Minutes