Table 1.3 Current and power dissipation

Mode of

 

Typical RMS current (*1) [mA]

 

Typical Power (*2) [watts]

Operation

 

 

 

 

 

 

+12 V

 

 

+5 V

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Model

MPB

MPB

MPB

 

All Models

MPB

MPB

MPB

 

3021AT

3032AT

3052AT

 

 

3021AT

3032AT

3052AT

 

 

MPB

MPB

 

 

 

MPB

MPB

 

 

3043AT

3064AT

 

 

 

3043AT

3064AT

 

 

 

 

 

 

 

 

 

Spin up

 

1300

 

 

460

 

17.9

 

 

 

1500 peak

 

 

600 peak

 

 

 

 

 

 

 

 

 

 

 

 

Idle (Ready)

115

140

185

 

460

3.68

3.98

4.52

(*3)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

R/W (On Track)

125

150

200

 

510

4.05

4.35

4.95

(*4)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Seek (Random)

335

360

410

 

510

6.57

6.87

7.47

(*5)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Standby

 

4

 

 

155

 

0.82

 

 

 

 

 

 

 

 

 

 

Sleep

 

4

 

 

110

 

0.60

 

 

 

 

 

 

 

 

 

 

*1 Current is typical rms except for spin up.

*2 Power requirements reflect nominal values for +12V and +5V power.

*3 Idle mode is in effect when the drive is not reading, writing, seeking, or executing any commands. A portion of the R/W circuitry is powered down, the spindle motor is up to speed and the Drive ready condition exists.

*4 R/W mode is defined as 50% read operations and 50% write operations on a single physical track.

*5 Seek mode is defined as continuous random seek operations with minimum controller delay.