Troubleshooting Guide (cont.)

WARNING:

Risk of electrical shock. Disconnect power before removal of any machine access panels.

Problem/Cause

Remedy

 

 

MACHINE DOES NOT POWER UP

 

 

 

Machine is unplugged

Ensure machine is plugged into power supply

 

 

Power switch in OFF position

Flip power switch to “ON” position (located at lower right corner

 

of back of machine); Blue LCD on door should be illuminated

 

when ON.

 

 

Branch circuit breaker has tripped

Reset circuit breaker at service supply panel

 

 

Power supply external fuse is blown

Check and replace fuse if necessary (located behind lower right

 

side chassis access panel).

 

 

NO HOT WATER FROM DISPENSE HEAD

 

 

 

Faulty water tank heater

Check heating element resistance; replace if necessary.

 

 

Water Fill circuit “watch dog timer” has tripped

Turn power switch “OFF” for 5 seconds, then “ON” (located at

 

lower right corner of back of machine)

 

 

Water supply to machine is turned OFF

 

 

 

Check for flashing diagnostic lights on control board

See diagram of control for explanation of lights.

 

 

Level probe sensitivity is too high

 

 

 

Water is disabled in programming

Check “Engineer” programming to ensure water is enabled.

 

 

NO CONCENTRATE IS DISPENSED

 

 

 

Bag-in-Box is empty or disconnected

Ensure Bag-in-Box is not empty; replace with new Bag-in-Box if

 

empty.

 

 

Bag-in-Box connector is pointing up. (This position can create a

Position Bag-in-Box connector pointing down to provide a

partial vacuum in the concentrate tube which may prevent

positive pressure in the concentrate tube.

product from being pumped to the dispense spout.)

 

 

 

Concentrate pickup tube is kinked

Inspect tubing routing and ensure concentrate tubing is not

 

kinked.

 

 

Concentrate pump tubing, product out switch, or Bag-in-Box

Periodically clean and sanitize tubing per the cleaning and

fitting is clogged.

sanitizing procedure in the instruction manual.

 

 

“Coffee” is disabled in programming.

Check “Engineer” programming to ensure “Coffee” is enabled.

 

 

WATER TANK OVERFLOWS THROUGH TANK VENT AT BOTTOM OF MACHINE

 

 

Weeping fill valve seat

Call for service.

 

 

WATER TANK OVERFLOWS THROUGH TANK VENT AT BOTTOM OF MACHINE

Note: A secondary float switch located in the water tank is intended to indicate an overflow condition at the LCD display.

Weeping water inlet valve

Check water inlet valve; replace if necessary. (Note: a slow

 

overflow indicated this condition.)

 

 

Page 17

Model LCD-2R and LCD-2A

 

 

Page 17
Image 17
Grindmaster LCD-2R, LCD-2A instruction manual Problem/Cause Remedy, Machine does not Power UP