600 W Power Supply Input Voltages
•100 - 127 V at 50 / 60 Hz 6.0 A
•200 - 240 V at 50 / 60 Hz 3.0 A
600 W Power Supply Output Voltages
The table below lists the total wattage available from the power subsystem for each voltage. For information about calculating the power usage for your configuration, see “Calculating Power Usage.”
| Table 5. Power Supply Output Capability | |
|
|
|
Voltage |
| Maximum Current |
|
|
|
+3.3 V |
| 20 Amp |
|
|
|
+5.0 V |
| 24 Amp |
|
|
|
+5.0 V Standby |
| 3 Amp |
|
|
|
+12.0 V1 |
| 16 Amp |
|
|
|
+12.0 V2 |
| 16 Amp |
|
|
|
+12.0 V3 |
| 16 Amp |
|
|
|
+12.0 V4 |
| 16 Amp |
|
|
|
| 0.5 Amp | |
|
|
|
Warning: Do not exceed a combined power output of 150 Watts for the +5 V and +3.3 V outputs. Exceeding a combined 90 Watts will overload the power subsystem and may cause the power supply to overheat and malfunction.
70 | Intel® Server System SR1520ML User’s Guide |