[i!i !! :,i_ !! :,i_ SECTION 4

KNOW ABOUT YOUR WATER SOFTENER

A. DIMENSIONS / SPECIFICATIONS

Pressure Drop (PSI) vs. Flow Rate (GPM)

 

35

 

 

30

 

 

25

 

m

 

 

co

 

 

13.

20

 

v

 

o.

 

 

O

 

 

lu

 

 

a

 

 

 

15

 

t_

 

 

"-

10

9,0 gp

13.

 

 

0I

0

2

4

6

8

10

12

14

16

18

20

22

24

Flow Rate (GPM)

Intermittent flow rate does not represent the maximum service flow rate used for determining the softeners

rated capacity and efficiency. Continuous operation at flow rates greater than the service flow rate may affect capacity and efficiency performance.

 

OTHER SPECIFICATIONS

 

 

 

 

 

 

 

Type

of ion exchange material (resin)

 

 

high capacity

 

 

Amount of resin

(cu ft)

 

 

 

 

1,19

 

 

Rated

Softening

Capacity

(Grains

@ Pounds

Salt Dose)

12,500

@ 2.5

 

 

 

 

 

 

 

 

 

 

 

33,300

@ 9.4

 

 

 

 

 

 

 

 

 

 

 

42,100

@ 16,2

 

 

Efficiency Rating

(Grains

/ Pound

of Salt @ Minimum Salt Dose)

5010

@ 2.5

 

 

Rated

Service

Flow Rate (gpm)

 

 

 

9.0

 

 

Pressure Drop

at Rated Service Flow

Rate (psi)

9

 

 

Max. Drain

Flow Rate (gpm) to Drain During Regeneration Cycle

2.3

 

This

system conforms

to

NSF/ANSI

44 for

the

specific

performance

claims as verified

and substantiated

by

test

data.

 

 

 

 

 

 

 

 

 

 

 

The efficiency rating is only valid at the minimum stated salt dose. These softeners were efficiency rated ac-

cording to NSF/ANSI Standard 44.