2-11. Matching Digital Voltage Control (DVC) Board To Welding Power Source

1 DVC Board PC1

2 DIP Switch

1

2

DVC SWITCH SETTINGS

 

S2

 

 

S1

 

 

 

 

 

1

2

1

2

3

4

5

 

 

DELTAWELD 300

 

 

 

ON

ON

 

ON

 

DELTAWELD 451, 450

 

O

 

 

ON

 

ON

 

DELTAWELD 651, 650

 

O

 

 

ON

ON

 

 

 

MAXTRON 300, 400

 

 

 

 

ON

 

ON

 

MAXTRON 450

ON

 

ON

 

 

ON

 

 

 

 

 

 

 

 

 

 

 

 

 

XMT 200/300

ON

 

 

ON

 

ON

 

 

 

 

 

 

 

 

 

 

 

 

 

ARC PAK 350

ON

 

 

ON

 

ON

 

 

 

SHOPMASTER 300

 

 

 

ON

ON

 

ON

 

 

DIMENSION 400

 

ON

 

 

ON

 

PULSTAR 450

 

 

ON

 

 

 

 

 

 

O – On For Optional Soft Start. Turn Off S1 -3.

 

 

 

 

– On For Optional Hot Start.

 

 

 

S-150 864-C