CWC Series Woodburning Fireplace

COMMON MATERIALS AND FACTORS

MATERIAL

K*

R

MINIMUM

THICKNESS

EH2416

0.458

1.09

0.50 in.**

(MHSC)

 

 

 

 

 

Common Brick

5.0

0.10

5.46 in.**

 

 

 

 

 

R Value is for 1/2 inch.

*Units of K = BTU/SQ FT/HR/˚F/IN ** Thickness of Listed Material

FP533ADD

Fig. 25 Hearth extension material factors.

Example of Determining Hearth Extension Equivalents

NEW

K of new material (per inch)

thickness

required

= ------------------------------------

X of listed

thickness

K of listed material (per inch)

material

To determine the thickness required for any new mate- rial:

Wall Covering

Noncombustible

Decorative

Facing

Seal all cracks between fireplace surround and wall materials with noncombustible material.

Noncombustible

Decorative

Covering

Hearth Extension

Insulation

Side View

2x4" Header - Do not notch at standoffs.

Seal crack between fireplace and hearth extension with noncombustible material.

Safety Strips -

Must be overlapped

Z\x" minimum.

Example for Common Brick

T (new) = 5.0 / 0.458 x 0.50 in. = 5.46 in. (new re- quired thickness).

FP550

Fig. 26 Sealing gaps.

16

87D1504

Page 16
Image 16