FLAME APPEARANCE

PLACING THE DECORATIVE ROCK

CAUTION

DO NOT sprinkle volcanic rock on the logs, around the pilot, or on or near burners. This may cause sooting. Place volcanic rock only on the floor of the fireplace.

During initial operation of the new heater, burning logs will give off a paper burning smell and orange flames will be present. Simply open the windows for a few hours to vent the odor.

Flames from the pilot and burner should be visually checked as soon as the heater is installed. In addition, periodically check the flames visually during operation.

CHECKING THE PILOT FLAME

The pilot flame must always be present when the heater is in operation. It should just touch the top of the ther- mocouple tip for natural. See Figure 33 for correct pilot flame.

If the pilot flame does not touch the thermocouple, then the main burner cannot function reliably. See Figure 34 for incor- rect shape of pilot flame.

MILLI-VOLT CONTROL AND THERMOSTAT CONTROL

Thermocouple

Thermocouple

for Natural

for Natural

Thermocouple

Thermocouple

for LP

 

for LP

Figure 33 - Correct Appearance of Pilot Flame

Figure 34 - Incorrect Appearance of Pilot Flame