30 / Installation
Installing base stations
Before installing wireless equipment, ensure that a site planner has determined base station locations and recorded them.
Before installing or relocating wireless equipment in the United States, verify that you have approval from UTAM Inc. by calling the Nortel Customer Response Center at
Positioning a base station
Avoid installing base stations on large concrete or marble columns. This affects radio coverage. If possible, place the base station at least 1m (40 in.) from such columns. Do not mount a base station where metalwork is near the antenna housings. Be careful not to damage existing wiring or panels.
Do not position base stations in ducts, plenums, or hollow spaces used to transport environmental air except where the duct, plenum or hollow space is created by a suspended ceiling having
•USA: a minimum of 54 in. and a maximim of 9 ft. 9 in. apart from the center of one base station to the center of the next
•Canada: a minimum of 9 cm and a maximim of 1.5 m apart from edge to edge
Never mount base stations in rows.