Specifications

Table 11 GS8048 Inverter Settings

Field

Item

Default

Minimum

Maximum

 

Aux Control

Off

 

Off, Auto or On

 

Aux Mode

Vent Fan

Load Shed, Gen Alert, Fault, Vent Fan, Cool Fan,

 

DC Divert, IEEE, Source Status, AC Divert

 

 

 

 

(Load Shed) ON: Batt >

56 Vdc

40 Vdc

 

72 Vdc

 

(Load Shed ON) Delay

30 Secs

6 Secs

 

1500 Secs

 

(Load Shed) OFF: Batt <

56 Vdc

48 Vdc

 

72 Vdc

 

(Load Shed OFF) Delay

18 Secs

6 Secs

 

1500 Secs

 

(Gen Alert) ON: Batt <

44 Vdc

40 Vdc

 

56 Vdc

 

(Gen Alert ON) Delay

30 Secs

6 Secs

 

1500 Secs

 

(Gen Alert) OFF: Batt >

56 Vdc

48 Vdc

 

72 Vdc

Auxiliary Output

(Gen Alert OFF) Delay

30 Secs

6 Secs

 

1500 Secs

 

(Vent Fan) ON: Batt >

56 Vdc

48 Vdc

 

72 Vdc

 

(Vent Fan) Off Delay

18 Secs

6 Secs

 

1500 Secs

 

(DC Divert) ON: Batt >

56 Vdc

48 Vdc

 

72 Vdc

 

(DC Divert ON) Delay

30 Secs

6 Secs

 

1500 Secs

 

(DC Divert) OFF: Batt <

44 Vdc

40 Vdc

 

56 Vdc

 

(DC Divert OFF) Delay

30 Secs

6 Secs

 

1500 Secs

 

(AC Divert) ON: Batt >

56 Vdc

48 Vdc

 

72 Vdc

 

(AC Divert ON) Delay

30 Secs

6 Secs

 

1500 Secs

 

(AC Divert) OFF: Batt <

44 Vdc

40 vdc

 

56 Vdc

 

(AC Divert OFF) Delay

30 Secs

6 Secs

 

1500 Secs

 

Aux Control

Off

 

Off, Auto or On

 

Aux Mode

Gen Alert

Load Shed, Gen Alert, Fault, Vent Fan, Cool Fan,

 

DC Divert, IEEE, Source Status, AC Divert

 

 

 

 

(Load Shed) ON: Batt >

56 Vdc

40 Vdc

 

72 Vdc

 

(Load Shed ON) Delay

30 Secs

6 Secs

 

1500 Secs

 

(Load Shed) OFF: Batt <

56 Vdc

48 Vdc

 

72 Vdc

 

(Load Shed OFF) Delay

18 Secs

6 Secs

 

1500 Secs

 

(Gen Alert) ON: Batt <

44 Vdc

40 Vdc

 

56 Vdc

 

(Gen Alert ON) Delay

30 Secs

6 Secs

 

1500 Secs

Auxiliary

(Gen Alert) OFF: Batt >

56 Vdc

48 Vdc

 

72 Vdc

(Gen Alert OFF) Delay

30 Secs

6 Secs

 

1500 Secs

Relay

 

(Vent Fan) ON: Batt >

56 Vdc

48 Vdc

 

72 Vdc

 

 

 

(Vent Fan) Off Delay

18 Secs

6 Secs

 

1500 Secs

 

(DC Divert) ON: Batt >

56 Vdc

48 Vdc

 

72 Vdc

 

(DC Divert ON) Delay

30 Secs

6 Secs

 

1500 Secs

 

(DC Divert) OFF: Batt <

44 Vdc

40 Vdc

 

56 Vdc

 

(DC Divert OFF) Delay

30 Secs

6 Secs

 

1500 Secs

 

(AC Divert) ON: Batt >

56 Vdc

48 Vdc

 

72 Vdc

 

(AC Divert ON) Delay

30 Secs

6 Secs

 

1500 Secs

 

(AC Divert) OFF: Batt <

44 Vdc

40 vdc

 

56 Vdc

 

(AC Divert OFF) Delay

30 Secs

6 Secs

 

1500 Secs

Inverter Stacking

Stack Mode

Master

 

Master, Slave

 

 

 

 

 

 

Power Save

Master Power Save Level

0

0

 

31

(in Stacking Menu)

Slave Power Save Level

1

1

 

31

 

Grid-Tie Enable

Y

 

Y or N

Grid-Tie Sell

Sell Voltage

52 Vdc

40 Vdc

 

60 Vdc

 

Grid-Tie Window

IEEE

 

IEEE or user

 

Input Voltage

0

-7

 

7

Calibrate

Output Voltage

0

-7

 

7

 

Battery Voltage

0

-0.8

 

0.8

48

900-0020-01-00 Rev A

Page 50
Image 50
Outback Power Systems GS8048 manual Field Default Minimum Maximum