Administrator’s Guide - SoundPoint® IP / SoundStation® IPInstallation and Operation

Name

Possible Values

Description

 

 

 

Provisioning

any string

The URL used in XML post/response transac-

Stringb

 

tions. If empty, the configured URL is used.

 

 

This field is disabled when Provisioning Method

 

 

is Default.

 

 

 

a.The server user name and password should be changed from the default values. Note that for insecure protocols the user chosen should have very few privileges on the server.

b.Not available on SoundPoint® IP 300 and SoundPoint® IP 500 phones.

2.2.1.3.4Ethernet Menu

Name

Possible Values

Description

 

 

 

CDP

Enabled, Disabled

If enabled, the phone will use CDP. It also reports

 

 

power usage to the switch.

 

 

 

VLAN ID

Null, 0 through 4094

Phone’s 802.1Q VLAN identifier.

 

 

Note: Null = no VLAN tagging

 

 

 

LANa

Auto, 10HD, 10FD,

The network speed over the Ethernet.

 

100HD, 100FD

The default value is Auto.

 

 

 

 

 

PCa

Auto, 10HD, 10FD,

The network speed over the Ethernet.

 

100HD, 100FD

The default value is Auto.

 

 

 

 

 

a.Only available on SoundPoint® IP 430 and 601 phones. HD means half duplex and FD means full duplex.

2.2.1.4Reset to Factory Defaults

The basic network configuration referred to in the preceding sections can be reset to factory defaults.

To perform this function, do one of the following during the countdown process in the bootROM:

On all phones except the IP 430 and 4000, simultaneously press and hold the 4, 6, 8 and * dial pad keys until the password prompt appears.

On the IP 430, simultaneously press and hold the 1, 3, 5 and 7 dial pad keys until the password prompt appears.

On the IP 4000, simultaneously press and hold the 6, 8 and * dial pad keys until the password prompt appears.

Enter the administrator password to initiate the reset. Resetting to factory defaults will also reset the administrator password (factory default password is 456).