Message

Description

Action

 

 

 

 

 

 

 

Files too big

Handset software download files are

Download new software from the SpectraLink

 

 

 

incorrect or corrupted.

site per section 8 Software Maintenance.

 

 

 

 

 

 

 

Flash config error

Handset internal configuration is corrupt.

Perform "Restore Defaults" operation via

 

 

 

 

administrator menus [or reprogram with

 

 

 

 

Configuration Cradle].

 

 

 

 

 

 

 

Initializing …

The handset is performing power on

None. This is informational only.

 

 

 

initialization.

 

 

 

 

 

 

 

 

Internal Err. # #

The handset has detected a fault from

Record the error code so it can be reported.

 

 

 

which it cannot recover.

Turn the handset off then on again.

 

 

 

OE = Error while writing the Flash (return

If error persists, try registering a different

 

 

 

handset to this telephone port.

 

 

 

handset to factory).

 

 

 

If error still persists, contact SpectraLink

 

 

 

 

 

 

 

OF = No functional code (contact

Technical Support and report the error.

 

 

 

SpectraLink Technical Support).

 

 

 

 

 

 

 

 

Multiple GW Reg

y…y = Gateway IP address

Check each NetLink Telephony Gateway for

 

 

yyy.yyy.yyy.yyy

Handset received responses from

the handset’s MAC address on the Telephone

 

 

 

multiple gateways; displays IP address of

Line Configuration screen. Delete any

 

 

 

one responding gateway.

duplicate entries leaving only one entry on the

 

 

 

 

correct Telephone Gateway and port for this

 

 

 

 

handset.

 

 

 

 

 

 

 

Must Upgrade SW!

Handset software is incompatible with

Download new software from the SpectraLink

 

 

 

hardware.

site per section 8 Software Maintenance.

 

 

 

 

 

 

 

Net Busy

x…x = AP MAC address

Try the call again later.

 

 

xxxxxxxxxxxx

Handset cannot obtain sufficient

 

 

 

 

bandwidth to support a call; displays

 

 

 

 

MAC of failing AP.

 

 

 

 

 

 

 

 

No DHCP Server

Handset is unable to contact the DHCP

Check that DNCP is operational and

 

 

 

server.

connected to WLAN or use Static IP

 

 

 

 

configuration in the handset.

 

 

 

 

 

 

 

No ESSID

Attempted to run site survey application

Let handset come completely up.

 

 

 

without an ESSID set.

Statically configure an ESSID in the Admin

 

 

 

 

menu.

 

 

 

 

 

 

 

No Func Code

Handset software download files are

Reconfigure the handset to gain access to the

 

 

 

incorrect or corrupted.

WLAN and download new code.

 

 

 

 

 

 

 

No GW Response

y…y = Gateway IP address

Verify that the NetLink Telephony Gateway is

 

 

yyy.yyy.yyy.yyy

Handset has lost contact with the NetLink

properly configured.

 

 

 

Telephony Gateway.

 

 

 

 

Handset cannot find an NetLink

 

 

 

 

Telephony Gateway.

 

 

 

 

Handset not registered on NetLink

 

 

 

 

Telephony Gateway.

 

 

 

 

 

 

 

 

 

NetLink Telephony Gateway is not

Verify that the NetLink Telephony Gateway is

 

 

 

working

powered on. If so, follow standard NetLink

 

 

 

 

Telephony Gateway troubleshooting

 

 

 

 

procedures.

 

 

 

No LAN connection at the AP or NetLink

Verify NetLink Telephony Gateway connection

 

 

 

Telephony Gateway.

to LAN and all APs.

 

 

 

 

 

 

PN: 72-1065-09-J.doc