Application Example

 

 

 

 

Add the

Use the following instructions to add a master device (the selected controller board)

Controller Board to your configuration project.

 

 

 

 

 

Step

Action

 

Comment

 

 

 

1

To create a new project, choose New from the

A new project window appears. Default project

 

File menu.

 

components are already in the project view.

 

 

 

2

In the project window, select (left-click) the

A selection box appears around the Controller Board

 

Controller Board icon.

icon.

 

 

 

3

Right-click on the Controller Board icon, scroll down,

The Select Controller Board dialogue box appears.

 

and left-click Type.

 

 

 

 

4

From the Available Types list, select your

In this case, select the IBS/4K.

 

controller board.

 

 

 

 

 

Adding the

 

 

If you have Schneider’s device database (Schneider_Device_DB), you can import it

Island Slave

into CMD. The following instructions are for manually creating a new configuration-

 

 

specific device when a configured one is not available:

 

 

 

 

Step

Action

 

Comment

 

 

 

1

In your configuration, right-click on the Controller

The Insert Device Description dialogue box appears.

 

Board icon, scroll down, and left-click Insert ID Code.

 

 

 

 

2

In the ID Code field, enter the ID code for your island.

Use 51 (33h) for the ID code data type of the sample

 

 

 

island.

 

 

 

3

In the Process Data Channel field, enter your island’s

The sample island assembly’s input data length is 80

 

process data length.

bits and the output data length is 64 bits (including the

 

 

 

control and status words).

 

 

 

4

At Device Type, select Remote Bus Device.

The Advantys island is always configured as a remote

 

 

 

bus device.

 

 

 

5

In the Station Name field, enter a station name for

Choose your own station name for the Advantys

 

your island node.

island.

 

 

 

6

In the Device Name field, enter a name for your

Choose your own device name for the Advantys

 

island node.

 

island.

 

 

 

7

In the Manufacturer Name field, enter a name for

Enter Schneider for the manufacturer name.

 

your island node.

 

 

 

 

8

In the Device Type field, enter a name for your

Enter a device type that you feel describes the nature

 

island node.

 

of the Advantys island. I/O will suffice.

 

 

 

 

Saving and

 

 

You can save your configuration with the standard Windows commands in the

Downloading the

File menu. The Online menu provides options for downloading and debugging

Configuration

your configuration.

 

 

 

 

 

890USE19600 April 2004

51

Page 51
Image 51
Schneider Electric INTERBUS Basic Network Interface Module, 890USE19600 Version 1.0 Adding, Island Slave, Downloading