2. Fan state:

Display

Corresponding mode

0Off

1Low fan

2High fan

3.Opening degree of EXV:

Opening degree equals the display data times 8; 4. Number of indoor unit

The indoor unit that can communicate with outdoor unit normally.

7.11 Outdoor fan speed control

There is one fan with two-speed, the fan speed is controlled according ambient temp. After the compressor stop, 30 seconds later the fan stop.

When cooling:

Ambient temp.rise

> 27

High speed

<27

Low speed

 

Ambient

>25

High speed

temp.decline

<25

Low speed

When heating:

 

 

Ambient temp.rise

> 14

Low speed

<14

High speed

 

Ambient

>12

Low speed

temp.decline

<12

High speed

7.12 Oil return function

If operation frequency is lower than 54Hz in 2 hours consecutively, it will be increased to 62Hz for 3 minutes. Then it recovers to the former operation frequency.