Instructions for the installer

3.2 Burner and nozzle characteristics table

Burner

Auxiliary

Semi rapid

Rapid

WOK

ULPG (PROPANE) – 2.75 KPa

Nominal gas consumption

 

Injector

(MJ/h)

 

(mm)

 

 

 

3.9

 

0.54

 

 

6.3

 

0.68

 

 

10.8

 

0.88

 

 

12.8

 

1.00

Burner

NG – 1.0 KPa

 

 

Nominal gas consumption

 

Injector

 

 

(MJ/h)

 

(mm)

 

 

 

 

Auxiliary

 

3.7

 

0.90

 

 

 

 

Semi rapid

 

6.5

 

1.20

 

 

 

 

Rapid

 

10.9

 

1.55

 

 

 

WOK

 

12.7

 

1.75

3.3Arrangement of burners on cooking hob

BURNERS

1

Auxiliary

2

Semi rapid

3

Rapid

4

WOK

5

WOK

4. FINAL OPERATIONS

After replacing the nozzles, reposition the flame-spreader crowns, the burner caps and the grids.

After adjustment to a different kind of gas from the one for which the cooker has been tested, replace the plate inside the storage compartment with one corresponding to the new kind of gas. This plate can be obtained from your nearest Authorised Assistance Centre.