APPENDICES

11.2 RING CADENCE CONFIGURATION

Using the above notation, the BNF description for the ring cadence patterns is as follows:

Timeval ::= time in milliseconds Repeatval ::= # of cycles to repeat

Tonename ::= "RING_0" "RING_1" "RING_2" "RING_3" "RING_4" "RING_5" "RING_6" "RING_7" "RING_8" "RING_9"

Idle ::= "IDLE"

Active ::= "ON" "OFF"

Inactive ::= Idle "(" Timeval ")"

Active ::= Active "(" Timeval ")" Sequence ::= Active Active "," Sequence Repetition ::= "[" Sequence "]" Repeatval Repeat ::= "R"

Cycle ::= Sequence Repetition

Fullsequence ::= Cycle Cycle "," Fullsequence Cadence ::= Fullsequence Fullsequence "," Repeat

Fullsequence"," Inactive "," Repeat Ring ::= Cadence

EXAMPLE RING CADENCE CONFIGURATION

200ms

100ms

200ms

200ms

100ms

200ms

 

300ms

400ms

 

4000ms

300ms

400ms

4000ms

1 cycle

For the ring cadence pattern above, the configuration would be:

RING_0 ON(200),OFF(300),ON(100),OFF(400),ON(200),OFF(4000),R

The Bellcore standard ring cadence patterns are:

NAME VALUE

RING_0 ON(2000),IDLE(4000),R

RING_1 ON(800),OFF(400),ON(800),IDLE(4000),R

27 Teledex IP250D User’s Guide SIP/MGCP

Part Number 600-0480-60

Page 32
Image 32
Teledex IP250DVoIP manual Example Ring Cadence Configuration