Modes and Initial Switch Settings

5.1 Modes and Initial Switch Settings

With this unit it is possible to switch the operating modes to suit the intended use. All mode settings can be set with switches. Table 5±1 summarizes the modes and initial switch settings.

Table 5±1. Modes and Initial Switch Settings

Function

Initial Setting

Setting Switch

 

 

 

Shutter speed switch

Ð

Rear panel SW1

Gain (sensitivity)

Fixed gain

Rear panel SW2

- Fixed gain

 

 

- Variable gain

 

 

- AGC

 

 

Electronic shutter

OFF

Rear panel SW3 ± 1, 2

- OFF

1/60 seconds

 

-continuous shutter

-Random shutter (V fixed)

-Random shutter (V reset)

-VI shutter (optional exposure period)

Internal/External Sync

Internal sync

Rear panel SW3 ± #, 4

Interlace/Non-Interlace

Interlace

Rear panel SW3 ± 5

Sync signal input/output impedance

75Ω

Rear panel SW4

- 75Ω/150Ω/100kΩ

 

 

Gain variable volume

Ð

Rear panel VR1

Sync signal input/output

Input

Clock board SW1

Optional input/output shutter

monitor out

Clock board S1

- Shutter monitor output

 

 

- Pixel clock output

 

 

γ switch characteristics

γ = 1

Process board SW1

- γ = 1/0.45

 

 

Output signal coupling

AC combined output

Process board SW4

- AC combined out/DC output

 

 

Outline emphasis circuit (PIH only)

OFF

Process board SW2

 

 

 

5-2