Pentair quick start After Powering up IntelliChlor, Reverse Cycle Self Cleaning Hours

Page 2

After Powering up IntelliChlor

After powering up the IntelliChlor, the light sequence at power up will be:

Salt lights will scroll back and forth, showing salt has not been checked yet

PWR light will be green.

CELL light will be off

LIFE light will be green steady or flashing if over warranty

FLOW light will reflect the water flow, either red or green

LIFE light will be green steady or flashing if over warranty

SANITIZER OUTPUT will be the output setting, as set by the MORE or LESS buttons or from the IntelliTouch, EasyTouch, or SunTouch control system

Note: If the IntelliChlor is connected to an IntelliTouch, EasyTouch, or SunTouch control system, the SANITIZER OUTPUT lights may slowly flash when the output is set to a value not exactly 20%, 40%, 60%, 80% or 100%.

Reverse Cycle (Self Cleaning Hours)

The Reverse cycle is set to two (2) hours for the first 192 hours of operation (approximately 30 days), then automatically switches to three (3) hours. To extend blade life, you may lengthen this cycle up to five (5) hours. See page 8 in the IntelliChlor User’s Guide for more information.

Press and hold the LESS button for three (3) seconds. The SANITIZER OUTPUT will display the number of hours of reversal:

-Two (2) lights on is two (2) hours

-Three (3) lights on is three (3) hours, etc.

Super Chlorinate Mode

Press MORE and LESS buttons simultaneously to active BOOST mode, which sets the sanitizer output to 100% for 24 hours.

Press both buttons again to cancel this mode.

If connected to an IntelliTouch, EasyTouch, or SunTouch control system, the MORE and LESS buttons are disabled. Super Chlorination must be activated from automation control panel.

Operating IntelliChlor in Water Temperatures below 52° F

When the IntelliChlor is operated in water temperatures 52° F and below, the CELL light will remain off. This feature extends the blade life. To verify the cell is in this cold water cutoff, press and hold the MORE button for three (3) seconds until the lights scroll across the display. The CELL light will be red to show it is in cold water cutoff, or green for normal operation.

Technical Support: Phone: (800) 831-7133

www.pentairpool.com - www.staritepool.com

© 2007 Pentair Water Pool and Spa, Inc. All rights reserved

1620 Hawkins Ave., Sanford, NC 27330 (919) 566-8000 -10951 West Los Angeles Ave., Moorpark, CA 93021 (805) 553-5000

IntelliChlor® and Pentair Water Pool and Spa® are trademarks and/or registered trademarks of Pentair Water Pool and Spa, Inc. Unless noted, names and brands of others that may be used in this document are not used to indicate an affiliation or endorsement between the proprietors of these names and brands and Pentair Water Pool and Spa, Inc. Those names and brands may be the trademarks or registered trademarks of those parties or others.