P3000iE QUICK START GUIDE
This Quick Start Guide is not a substitute for reading the Operator’s Manual.
To reduce the risk of injury or death, user must read and understand Operator’s Manual before using this product.
Do not connect to a building’s electrical system unless the generator and transfer switch have been verified by a qualified electrician. The connection must isolate the generator power from utility power and must comply with all applicable laws and electrical codes.
DANGER
Using a generator indoors CAN KILL YOU IN MINUTES.
Generator exhaust contains carbon monoxide. This is a poison you cannot see or smell.
| | | | | | | | | | | | | | | | | | | | | | | | | | |
NEVER use inside a home | Only use OUTSIDE and |
or garage. EVEN IF doors | far away from windows, |
and windows are open. | doors, and vents. |
7.Position the FUEL VALVE to ON.
8.Turn the ignition key to START position. When the engine starts, release the key.
OFF ON
PROBLEM | POSSIBLE CAUSE | SOLUTION |
| | |
Engine will not start. | - Engine switch is off. | - Turn engine switch to ON. |
| - No fuel. | - Fill fuel tank. |
| - Stale fuel or water | - Drain entire fuel system |
| in fuel. | and refill with fresh fuel. |
| - Engine oil level is low. | - Engine is equipped with |
| - Spark plug faulty, fouled | Low Oil Shutoff. If the |
| or improperly gapped. | engine oil level is |
| - Choke lever is in | low, the unit will not start. |
| Check engine oil |
| RUN position. |
| level and fill if necessary. |
1.Add engine lubricant per the Operator’s Manual instructions.
Oil fill recommendations using included oil fill bottle:
P3000iE
3 oil fill bottles up to #2 mark
Always verify oil level is at upper limit mark on dipstick before operating.
2. | Connect Battery Cables to | 3. | Install and tighten battery |
| positive (+) and negative (-) | | holder over battery. |
| terminals. | | |
| Slide boots over cables | | |
| and terminals. | | |
4.Fill the fuel tank per the Operator’s Manual instructions.
NOTICE:
Do not use E15 or E85 fuel
(or fuel containing greater than 10% ethanol) in this product. It is violation of federal law and will damage the unit and void your warranty.
5. | Position the SMART | 6. | Pull CHOKE knob out to |
THROTTLE switch to | choke engine. |
| OFF. | | CHOKE |
| | | |
| | | | |
| | | | |
| | | | |
9. | Once the engine is running, | 10. | After a 2-3 minute warm up, |
slowly push the choke knob | Position the SMART |
| in to the RUN position. | | THROTTLE switch to ON. |
| CHOKE | | |
| | | |
Stopping The Unit
1. | Disconnect all appliances | 2. | Allow the engine to cool. |
connected to the generator. | Turn the FUEL VALVE |
| Position the Ignition Switch | | to OFF. |
| to OFF. | | | |
| OFF | ON | | |
| | START | | FUEL VALVE |
| | | |
USING THE GENERATOR
Connect devices to be powered by following the steps below.
-Make sure the total rated power from the items you plan to use at the same time are less than the generator continuous (running) watts. Make sure the total surge (starting) power from the items you plan to use at the same time are less than the generator maximum watts. See Operator’s Manual to calculate total amount of power needed.
-Start the generator with nothing connected.
-Plug in and turn on the first load (perferably the largest load).
-Allow the generator output to stabilize (engine runs smoothly and attached device operates properly).
-Repeat previous steps for additional loads.
IMPORTANT: Never add more load than the generator’s capacity. Please consider surge load when determining total power need.
STORING THE UNIT
When preparing to store the generator, allow the unit to cool completely. If the unit is going to be stored for more than 4 weeks, turn off generator by turning fuel valve to the OFF position. After the generator stops running, turn key to the OFF position. Follow complete storage instructions in Operator’s Manual.
| - Refueled with bad | START position. |
| - Drain fuel and carburetor. |
| fuel. |
| - Dirty fuel filter. | Refuel with fresh |
| fuel. |
| |
| | - Contact authorized |
| | service dealer. |
| | |
Engine hard to start. | - Water in fuel. | - Drain entire system and |
| - Weak spark at spark plug. | refill with fresh fuel. |
| | - Contact authorized |
| | service dealer. |
| | |
Engine lacks power. | - Dirty air filter. | - Check air filter element. |
| - Engine stored without | - Clean or replace as |
| treating or draining | needed. |
| fuel, or refueled with | - Drain fuel and carburetor. |
| bad fuel. | - Refuel with fresh fuel. |
| |
| | |
AC receptacle does not work. | Item plugged in is defective. | - Try a different item. |
| Overload indicator on (light | - Press reset button. |
| solid) | |
DC receptacle does not work. | - Circuit protector engaged. | - Remove any load from |
| - Item plugged in is defective. | the generator. |
| | - Replace the fuse, |
| | then depress the DC |
| | circuit breaker. |
| | - Try a different item. |
| | |
Generator makes a “spark | - If knocking or pinging | - Switch to a different |
knock” or “pinging” noise. | occurs under normal load | brand of fuel with |
| at a steady engine | a octane rating of 86 or |
| speed, the problem may | higher. |
| be with the fuel | - Contact authorized |
| being used. | service dealer. |
| - An occasional light | |
| “knocking” or “pinging” | |
| under heavy load is not a | |
| cause for concern. | |
If problems persist after trying the above solutions, contact your authorized service dealer.
The following symptoms may indicate problems that will affect the emissions level on the unit.
-Hard starting or stalling
-Rough idle
-Misfiring or backfiring under load
-Afterburning (backfiring)
-Black exhaust smoke or high fuel consumption
If you encounter any of these symptoms, take the unit to your authorized service dealer for service.