Porter-Cable BSI525 instruction manual Operation

Page 10

OPERATION

KNOW YOUR GENERATOR

Read this General Manual and Safety Rules before operation of your Generator. Compare the illustration in your parts manual with your generator to familiarize yourself with the location of various controls and adjustments. Save all manuals for future references.

GENERATOR CAPACITY

IMPORTANT: Exceeding the rated capacity of your generator can result in serious damage to your generator and connected electrical devices. See the Wattage Calculation section in this manual to assist you in determining the appliances and tools that can be run with the wattage capacity of your generator.

CIRCUIT BREAKERS

Each receptacle has a circuit breaker to protect the generator from overloading. If the circuit breaker trips, unplug all electrical loads from the generator. Let the circuit breaker cool down. Push circuit breaker button to reset.

LOW OIL PROTECTION

To protect the generator engine from damage, the engine is equipped with a Low Oil Protection reliability feature.

When the engine has been shut down for refueling or other purposes and the oil level is low, the Low Oil Protection will prevent the engine from restarting until sufficient oil has been added. NOTE: The Low Oil Protection mechanism is very sensitive. You must fill the engine to the full mark on the dipstick to inactivate this safety device.

IMPORTANT: Low Oil Protection will not automatically shut down the engine if oil level becomes low while the engine is running. Always check engine oil level before starting the engine.

BEFORE START UP

This generator has been shipped from the factory without oil in the crankcase. Operating the unit without oil can damage the engine.

Always check engine oil level before every start. Running engine low of oil or out of oil could result in serious damage to the engine.

Follow the steps listed below before starting generator:

1.Check engine oil. Refer to the Engine Operator's Manual for correct grade and quantity of oil.

2. Check fuel level, fill as required. Make sure generator is turned off and has been allowed time to cool down. Use clean, fresh, regular unleaded gasoline with a minimum of 87 octane. Do not mix oil with gasoline.

Never fill fuel tank completely. Fill tank to 1/2" below the bottom of the filler neck to

provide space for fuel expansion. Wipe any fuel spillage from engine and equipment before starting engine.

Never fill fuel tank indoors. Never fill fuel tank when engine is running or hot. Do not smoke when filling fuel tank.

Never run engine indoors or in enclosed, poor ventilated areas, en- gine exhaust contains carbon monoxide, an odorless and deadly

gas.

3.Make sure generator is grounded in accordance with local requirements.

4.All electrical loads MUST be disconnected.

D26082

10- ENG

Image 10
Contents Generator Specifications Consumer Safety InformationWhen installing a Double Safety Guidelines / DefinitionsImportant Safety Instructions Risk of Electrocution and FireOperation When damagedRisk of Electrocution and Fire Generator in rainUnit Indoors or in ANY Risk of FireConfined Area Risk of Breathing Inhalation Hazard Risk of Unsafe OperationRisk of HOT Surfaces Risk of Moving Parts AssemblyRemove Generator from Carton Risk from LiftingObtaining Electricity from the Generator Double Throw Transfer SwitchGrounding the Generator Extension CordsOperation To Start the Engine Connecting Electrical Loads Stopping EngineGenerator Maintenance MaintenanceEngine Maintenance Customer Responsibilities TableEngine Preparation StorageGenerator Wattage Calculations Determining Wattage RequirementsApplication Guide Starting Wattage RequirementsHousehold Wattage Calculator Appliance or Load Device Typical Device Wattage TotalTroubleshooting Guide StartLimited Warranty Quick Facts Call