STARTING A WARM ENGINE
1.Move ON/OFF switch to the ON position.
2.Move the choke lever to the HALF CHOKE position.
3.Squeeze and hold the throttle trigger. Keep throttle trigger fully squeezed until the engine runs smoothly.
4.Pull starter rope sharply until engine runs, but no more than 5 pulls.
5.Allow engine to run 15 seconds, then move the choke lever to the OFF CHOKE position.
NOTE: If engine has not started, pull starter rope 5 more pulls. If engine still does not run, it is probably flooded.
STARTING A FLOODED ENGINE
Flooded engines can be started by placing the choke lever in the OFF CHOKE position; then, pull the rope to clear the engine of ex- cess fuel. This could require pulling the starter handle many times depending on how badly the unit is flooded.
If the unit still doesn’t start, refer to TROUBLESHOOTING TABLE or call
OPERATING THE COUPLER
This model is equipped with a coupler which enables optional attachments to be installed. The optional attachments are:
MODEL:
Edger . . . . . . . . . . . . . . . . . . . . . . .PP1000E Cultivator . . . . . . . . . . . . . . . . . . .PP2000T Blower . . . . . . . . . . . . . . . . . . . . . .PP3000B Brushcutter . . . . . . . . . . . . . . . . . PP4000C
WARNING: Always stop unit and dis- connect spark plug before removing or instal- ling attachments.
REMOVING PRUNER ATTACHMENT (OR OTHER OPTIONAL ATTACH- MENTS)
CAUTION: When removing or installing at-
tachments, place the unit on a flat surface for stability.
1.Loosen the coupler by turning the knob counterclockwise.
Upper Tube
Coupler
3.While securely holding the engine and upper tube, pull the attachment straight out of the coupler.
INSTALLING OPTIONAL ATTACH- MENTS
1.Remove the tube cap from the attach- ment (if present).
2.Position locking/release button of attach- ment into guide recess of coupler.
3.Push the attachment into the coupler until the locking/release button snaps into the primary hole.
4.Before using the unit, tighten the knob se- curely by turning clockwise.
Coupler | Primary Hole |
| Guide Recess |
Upper | Locking/ Attachment |
Tube | Release |
| Button |
WARNING: Make sure the locking/ release button is locked in the primary hole and the knob is securely tightened before op- erating the unit.
INSTALLING ATTACHMENT
HANGER
An attachment hanger is provided for storage when attachment is not in use.
To install hanger on attachment:
1.Remove the tube cap from the attach- ment (if present) and discard.
2.Press and hold the locking/release button.
3.Push hanger onto the attachment until the locking/release button snaps into the hole.
OPERATING POSITION
ALWAYS WEAR:
Head
Protection Eye
Protection
Lower
LOOSEN
Attachment
TIGHTEN Knob
Long Pants
Heavy Shoes
2. Press and hold the locking/release button.
Locking/Release |
| DANGER: Do not extend arms above | |
Button |
| shoulders while pruning. Do not stand be- | |
|
| neath branch being cut. | |
Coupler | Upper Tube | WARNING: Always wear head, eye, | |
Lower Attachment | hearing, foot and body protection to reduce | ||
| |||
| the risk of injury when operating this unit. | ||
|
|
11