Oregon Scientific WMR968 user manual Indoor Humidity, Outdoor and Channel Humidity

Page 5

To select the display unit,

1.Press the indoor temperature window.

2.Press [UNIT] repeatedly for the desired setting. The selected unit will apply to all temperature displays in this window.

Note: The unit of all temperature related display will be changed simultaneously.

To display the dew point temperature, press the indoor temperature window until the “DEW” indicator is displayed.

To display maximum, minimum temperatures,

1.Press the indoor temperature window or repeately until "DEW" icon appear.

2.Press [MEMORY] repeatedly for the desired record. The time and date of the record will also be displayed alternatively with “STAMP” icon in the clock window.

The display will automatically return to the current temperature or dew temperature whatever is displayed before if the unit is left untouched for about one minute.

To clear the memory,

1.Press the indoor temperature window or repeately until "DEW" icon appear.

2.Press and hold [MEMORY] till the key tone is heard.

3.Press [MEMORY] to check the memory is clear.

INDOOR HUMIDITY

The current indoor relative humidity, taken by the indoor baro- thermo-hygrometer, is displayed on the indoor hygrometer window.

To display the maximum, minimum and current humidity,

1.Press the indoor humidity window.

2.Press [MEMORY] repeatedly for the desired record. The time and date of the record will also be displayed alternatively with “STAMP” icon in the clock window.

To clear the memory,

1.Press the indoor humidity window.

2.Press and hold [MEMORY] till the key tone is heard.

3.Press [MEMORY] to check the memory is clear.

GB

The temperatures can be displayed in degree Centigrade (°C) or Fahrenheit (°F).

To select the display unit,

1.Press the outdoor/channel temperature window.

2.Press [UNIT] repeatedly for the desired setting. The selected unit will apply to all temperature displays in this window.

Note: The unit of all temperature related display will be changed simultaneously.

To display the maximum, minimum temperatures,

1.Press the outdoor/channel temperature window or repeately until "DEW" icon appear.

2.Press [CHANNEL] for the outdoor thermo-hygrometer or the desired channel.

3.Press [MEMORY] repeatedly for the desired record. The time and date of the record will also be displayed alternatively with “STAMP” icon in the clock window.

To display the dew point temperature for a channel, press the window again when the channel temperature is located.

To clear the memory,

1.Press the outdoor/channel temperature window or repeately until "DEW" icon appear.

2.Press [CHANNEL] for the outdoor thermo-hygrometer or the desired channel.

3.Press and hold [MEMORY] till the key tone is heard.

4.Press [MEMORY] to check the memory is clear.

OUTDOOR AND CHANNEL HUMIDITY

The relative humidity readings taken by the outdoor thermo- hygrometer and separate thermo-hygro sensors are displayed on the outdoor/channel humidity window.

As this window can display up to four different sets of data, specify the instrument or channel you want to read.

To do so,

1.Press the outdoor/channel humidity window.

2.Press [CHANNEL] to go from the outdoor reading taken by the thermo-hygrometer to those taken by individual sensors (Channel 1, 2 or 3).

To display the maximum, minimum and current humidity,

OUTDOOR AND CHANNEL TEMPERATURES

The temperature readings taken by the outdoor thermo-hygrometer and separate thermo or thermo-hygro sensors are displayed on the outdoor and channel temperature window.

As this window can display up to four different sets of data, specify the instrument or channel you want to read.

To do so,

1.Press the outdoor/channel temperature window.

2.Press [CHANNEL] to go from the outdoor reading taken by the outdoor thermo-hygrometer to those taken by individual sensors (Channel 1, 2 or 3).

The outdoor thermo-hygrometer is also capable of detecting the dew point temperature as well as the wind chill reading. To display such information, press the window repeatedly.

5

1.Press the outdoor/channel humidity window.

2.Press [CHANNEL] for the outdoor thermo-hygrometer or the desired channel.

3.Press [MEMORY] repeatedly for the desired record. The time and date of the record will also be displayed alternatively with “STAMP” icon in the clock window.

To clear the memory,

1.Press the outdoor/channel humidity window.

2.Press [CHANNEL] for the outdoor thermo-hygrometer or the desired channel.

3.Press and hold [MEMORY] till the key tone is heard.

4.Press [MEMORY] to check the memory is clear.

928N-USE.p65

5

08/10/2001, 12:20 PM

Image 5
Contents WMR968 is also equipped with To install itStandard Package Original WMR968 comes complete with the followingRain Gauge THERMO-HYGROMETERSolar Transmitters BARO-THERMO-HYGROMETERMain Unit LOW-BATTERY WarningIndoor and DEW Point Temperatures Daily AlarmBacklight Calendar ClockOutdoor and Channel Humidity Outdoor and Channel TemperaturesIndoor Humidity Rainfall Wind Speed and Direction Weather AlarmsAuto Scanning Function Reset Button Disconnected SignalsMaintenance SpecificationsIntended USE of the Device FCCCustomer Assistance

WMR968 specifications

The Oregon Scientific WMR968 is a highly regarded wireless weather station that provides a comprehensive suite of meteorological data, making it an excellent choice for both amateur meteorologists and weather enthusiasts. This station is designed to offer real-time weather insights with accuracy and reliability.

One of the principal features of the WMR968 is its ability to collect a wide range of environmental data. It comes equipped with multiple sensors that measure temperature, humidity, wind speed, wind direction, and precipitation levels. The device is particularly noted for its wireless technology, which allows for easy placement of sensors around the property without the hassle of cables. This wireless capability ensures that users can monitor weather conditions from various locations, enhancing the practicality of the data collected.

The WMR968 boasts an impressive transmission range of up to 300 feet, allowing the sensors to communicate effectively with the main console located indoors. This feature is enhanced by the use of 433 MHz frequency, which minimizes interference and ensures a stable connection. The console itself is user-friendly, featuring a large LCD display that presents weather data in an easy-to-read format.

Another remarkable aspect of the Oregon Scientific WMR968 is its data logging capability. Users can track changes over time, storing historical data for up to 255 days. This feature is invaluable for analyzing weather patterns and trends. Additionally, the weather station supports the use of an optional USB data cable for connecting to a computer, enabling users to process or share their data more extensively.

In terms of technology, the WMR968 employs advanced sensor mechanisms that provide accurate and responsive readings. The anemometer and rain gauge design allow for precise wind and rainfall measurement, while the temperature and humidity sensors are designed for quick stabilization to ensure that the information displayed is always current.

Users will appreciate the customizable alerts and alarms available with the WMR968, allowing them to set thresholds for specific weather conditions. This feature is particularly useful for monitoring severe weather, ensuring users can take precautions when necessary.

Lastly, the Oregon Scientific WMR968 is compatible with additional sensors, enabling users to expand their weather monitoring capabilities. Overall, the WMR968 is a feature-packed weather station that combines advanced technology with user-friendly design, providing comprehensive weather monitoring to enhance understanding and safety. Whether for personal interest or professional use, the Oregon Scientific WMR968 stands out as a reliable tool in the realm of weather observation.