Omega Engineering CN9400 specifications Warranty / Disclaimer, Return REQUESTS/ Inquiries

Page 37

WARRANTY / DISCLAIMER

OMEGA ENGINEERING, INC. warrants this unit to be free of defects in materials and workmanship for a period of 37 months from date of purchase. OMEGA Warranty adds an additional one (1) month grace period to the normal three (3) years product warranty to cover handling and shipping time. This ensures that OMEGA’s customers receive maximum coverage on each product.

If the unit should malfunction, it must be returned to the factory for evaluation. OMEGA’s Customer Service Department will issue an Authorized Return (AR) number immediately upon phone or written request. Upon examination by OMEGA, if the unit is found to be defective it will be repaired or replaced at no charge. OMEGA’s WARRANTY does not apply to defects resulting from any action of the purchaser, including but not limited to mishandling, improper interfacing, operation outside of design limits, improper repair, or unauthorized modification. This WARRANTY is VOID if the unit shows evidence of having been tampered with or shows evidence of being damaged as a result of excessive corrosion; or current, heat, moisture or vibration; improper specification; misapplication; misuse or other operating conditions outside of OMEGA’s control. Components which wear are not warranted, including but not limited to contact points, fuses, and triacs.

OMEGA is pleased to offer suggestions on the use of its various products. However, OMEGA neither assumes responsibility for any omissions or errors nor assumes liability for any damages that result from the use of its products in accordance with information provided by OMEGA, either verbal or written. OMEGA warrants only that the parts manufactured by it will be as specified and free of defects. OMEGA MAKES NO OTHER WARRANTIES OR REPRESENTATIONS OF ANY KIND WHATSOEVER, EXPRESSED OR IMPLIED, EXCEPT THAT OF TITLE, AND ALL IMPLIED WARRANTIES INCLUDING ANY WARRANTY OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE ARE HEREBY DISCLAIMED. LIMITATION OF LIABILITY: The remedies of purchaser set forth herein are exclusive and the total liability of OMEGA with respect to this order, whether based on contract, warranty, negligence, indemnification, strict liability or otherwise, shall not exceed the purchase price of the component upon which liability is based. In no event shall OMEGA be liable for consequential, incidental or special damages.

CONDITIONS: Equipment sold by OMEGA is not intended to be used, nor shall it be used: (1) as a “Basic Component” under 10 CFR 21 (NRC), used in or with any nuclear installation or activity; or (2) in medical applications or used on humans. Should any Product(s) be used in or with any nuclear installation or activity, medical application, used on humans, or misused in any way, OMEGA assumes no responsibility as set forth in our basic WARRANTY/ DISCLAIMER language, and additionally, purchaser will indemnify OMEGA and hold OMEGA harmless from any liability or damage whatsoever arising out of the use of the Product(s) in such a manner.

RETURN REQUESTS/ INQUIRIES

Direct all warranty and repair requests/inquiries to the OMEGA Customer Service Department. BEFORE RETURNING ANY PRODUCT(S) TO OMEGA, PURCHASER MUST OBTAIN AN AUTHORIZED RETURN (AR) NUMBER FROM OMEGA’S CUSTOMER SERVICE DEPARTMENT (IN ORDER TO AVOID PROCESSING DELAYS). The assigned AR number should then be marked on the outside of the return package and on any correspondence.

The purchaser is responsible for shipping charges, freight, insurance and proper packaging to prevent breakage in transit.

FOR WARRANTY RETURNS, please have the following information available BEFORE contacting OMEGA:

1.P.O. number under which the product was PURCHASED,

2.Model and serial number of the product under warranty, and

3.Repair instructions and/or specific problems relative to the product.

FOR NON-WARRANTY REPAIRS, consult OMEGA for current repair charges. Have the following information available BEFORE contacting

OMEGA:

1.P.O. number to cover the COST of the repair,

2.Model and serial number of product, and

3.Repair instructions and/or specific problems relative to the product.

OMEGA’s policy is to make running changes, not model changes, whenever an improvement is possible. This affords our customers the latest in technology and engineering.OMEGA is a registered trademark of OMEGA ENGINEERING, INC.

© Copyright 1996 OMEGA ENGINEERING, INC. All rights reserved. This document may not be copied, photocopied, reproduced, translated, or reduced to any electronic medium or machine-readable form, in whole or in part, without prior written consent of OMEGA ENGINEERING, INC.

Image 37
Contents User’s Guide D e IndexInstallation Safety InformationConfiguration Ultimate Safety AlarmsC t Functions MenuI c k S t a r t Quick StartSPI.D SPI.DT r o d u c t i o n IntroductionTune CN9400E r v i e w OverviewSET-UP AutotuneFunctions CYCLE-TIMESET-UP Reminder of Instrument Adjustments Using Program ModeMenu Navigation N u N a v i g a t i o nT o t u n e AutotuneTune Program TuneTune AT Setpoint Program Proportional CYCLE-TIME Reminder of Instrument AdjustmentsCYCLE-TIME Selection Methods Proportional CYCLE-TIMECYCLE-TIME Recommendations CYC.TTo Pre-Select Cycle-time Before Autotune Pre-Select Automatic Acceptance of Any Autotune Cycle-timeRAMP-SOAK A m m e rSprr SoakSecond Setpoint SP2 To Configure SP2 AS AN AlarmC o n d S e t p SP2 Output and LED Indication States in Alarm Condition Subsidiary SP2 ModeC o n d S SP2.BData Error MessagesFail Read SP1 Output Percentage Power Using the CheK Control accuracy monitorImproving Control Accuracy N g C o n t r o l a c c u r a c yBand LevelDER.T DACCYC.T N c t i o n L i s tOfst SET.2Hisc DispLO.SC InptREU.D BurnSP1 SP2 Span REU.LZero ChekProg Auto StAY Program security using LockFactory SET Output Options Heat Cool Strategy Configuration Advanced SettingsV a n c e d S e t t i n g s Calibration to Another Instrument Heat Cool Strategy ConfigurationWater cooled applications Multi zone applicationsCalibration to Another Instrument Linear Input CalibrationV a n c e d S e t t G sC h a n i c a l Installation Mechanical InstallationDIN Panel Cutout DIN panel cutout sizeTo mount a Controller proceed as follows Minimum Spacing MountingWiring the Connector E c t r i c a l InstallationOutput Devices Output Device AllocationModel CN9412 Typical Connection Diagram L InstallationE c t r N s o r S e l e c t i o n Specification SpecificationReturn REQUESTS/ Inquiries Warranty / DisclaimerOmega.comTM

CN9400 specifications

The Omega Engineering CN9400 is a cutting-edge device designed for precision temperature control and monitoring in industrial and research applications. This versatile instrument is renowned for its high accuracy, stability, and user-friendly interface, making it an essential tool for engineers and technicians alike.

One of the standout features of the CN9400 is its advanced PID control algorithm. This method ensures that temperature fluctuations are minimized, allowing for precise temperature management in processes that require strict adherence to specific thermal conditions. The PID control system continuously calculates the error between a desired setpoint and a measured process variable, adjusting the control output to achieve optimal performance.

The CN9400 is equipped with a large, easy-to-read LCD display that provides real-time data on temperature readings and system status. Users can view both set point and actual temperature simultaneously, enabling quick and informed decisions during critical operations. Additionally, the display features customizable alerts and notifications that inform operators of any deviations or potential issues, ensuring a proactive approach to process control.

In terms of connectivity, the CN9400 offers a variety of options, including RS-232 and RS-485 communication protocols, enabling seamless integration into existing control systems. This connectivity ensures that users can monitor and control the device remotely, enhancing operational efficiency and flexibility.

Another noteworthy characteristic of the CN9400 is its robust construction. Designed for durability, it can withstand harsh industrial environments, including extreme temperatures and vibrations. The device is also compatible with various types of temperature sensors, such as thermocouples and RTDs, providing users with the flexibility to select the most appropriate sensor type for their specific application.

In addition to its technical capabilities, the Omega Engineering CN9400 is designed with user convenience in mind. The intuitive menu-driven interface allows for easy programming and operation. Users can quickly navigate through settings and parameters without extensive training, minimizing downtime and enhancing productivity.

Overall, the Omega Engineering CN9400 is a powerful and reliable temperature controller that combines advanced technology with user-friendly features. Its precision, durability, and connectivity make it an ideal choice for a wide range of industrial and research applications, ensuring accurate temperature management in even the most demanding environments.