Active Line Tracing

Active View Area

Bleed over

Checked-Active Frequencies

Clear Signal

Clipping

Common Bonding

Compound Field

Coupling

Crosshairs

Current Strength

Currently Available Frequencies

Default

Depth

Glossary -- Definitions

A mode of locating using a Line Transmitter to inject a chosen frequency onto a hidden conductor; the frequency is then detected by the SR-60 to trace the conductor

The area within the circle in the center of the operating screen, where the Tracing Line or Sonde Pole and Equator symbols appear.

Coupling of the signal from the target line onto adjacent conductors by any means (resistive, capacitive, or inductive). Bleed-over makes the signal appear to be coming from a different conductor than the one being traced by setting up a field of the same frequency in a nearby conductor.

A frequency is said to be “Checked-Active” when it has been checked on the main menu; this enables it to be accessed by the use of the Frequency Key during operation of the SR-60. The “In Use” frequency is always one of the Checked-Active set.

A clear signal is a field caused by current through a conductor which is strong enough to be detected unambiguously by a receiver such as the SR-60. Clear signals depend on good conductivity, good grounding, and adequate current through the target conductor.

The condition of receiving a signal too strong to be processed all at once by the signal processor; in the SR-60 this condition will cause a warning signal to flash. The signal peaks are too high and are “clipped” off.

The use of a connector to ground more than one line through the same ground connection. Phone lines, for example, are often bonded to ground via the electrical service ground line. Common bonding can be a cause of ambiguous signals in locating.

An electromagnetic field caused by the combination or two or more fields in proximity to each other. A compound field has multiple lobes and a complex energy pattern which can require analysis to interpret correctly when locating.

The transfer of energy (without direct electrical contact) between two or more cables or components of a circuit. This can occur through induction, through common bonding, or other means.

A symbol in the center of the Active View Area representing the location of the SR-60, relative to the detected field.

The calculated level of current based on field strength detected by the Omnidirectional antennas of the SR-60; expressed approximately in milliamps (mA). An accurate depth measure is required for accuracy.

Frequencies which have been checked in the Master Frequency Menu are said to be “Currently Available”; they appear on the Main Menu when the Menu Key is pressed, and can be set to “Checked-Active” status.

Default values are those settings which the SR-60 uses if the operator does not choose alternative settings; they can be restored from the Information Menu.

See “Measured Depth”

42

www.seektech.com

Ridge Tool Company  Elyria, Ohio  U.S.A

Image 44
Contents SeekTech SR-60 Patents PendingTable of Contents SeekTech SR-60 SeekTech SR-60General Safety Information Work Area SafetyElectrical Safety Battery PrecautionsRemove batteries entirely before shipping ServiceSR-60 Use and Care Important Notice SR-60 Components SR-60 ComponentsIntroduction to the SR-60 Getting StartedSR-60 Modes Display ElementsCommon Display Elements Display Elements Line Trace Mode Common Display ElementsDisplay Elements Sonde Mode Default FrequenciesSonde Mode Active Line Trace ModePower Passive Line Trace Mode KeypadStarting Up Low Battery WarningOperation Time Set up Activating FrequenciesSounds of the SR-60 Highlighting a Desired Frequency 8 kHzKey Items in Using the SR-60 Line Tracing with the SR-60Active Line Tracing Shutting DownTracing Line Showing Low Distortion Tracing Line Showing High Distortion Depth Warnings Measuring Depth Line Tracing ModesPush-Button Depth Clipping Tracing Modes Current and Signal Angle ReadingOperating Tips for Active Line Tracing Checking for Distortion Screen Display in Different Locations Line Tracing Passive Line Tracing There are also two higher radio frequency bandsOmniSeek Locating Selecting OmniSeekSonde Locating Operating Tips for Passive Line TracingWhen locating a Sonde, first set up the locate Location MethodsLocalize the sonde Pinpoint the SondeFloating Sondes Tilted SondesVerify the locate SimulTrace Measuring Depth Sonde ModeClipping Sonde Mode Screen Display in Different Locations Sonde Tilted Sonde, Poles, and Equator Custom User Frequencies Changing a User-Defined FrequencyMenus and Settings Auto Menu Exit Count-down TimerSimulTrace Mode OmniSeek ModeCurrently Available Sonde Frequencies Currently Available Active Line Trace FrequenciesOptional Features LCD ContrastDisplay Elements Menu Race Track and WatermarkSignal Focus Control Center Signal Strength OptionNo-Signal Icon Suppression Frequency Selection Control Sound Muting Î99’Tracing Line Response Information Screen and Restoring Defaults Restore Factory DefaultsMenu Tree Operating With the Distortion LineInformational Locating Over a Circular FieldBleed-over Better Way of Locating Advantages of the Omnidirectional AntennaWhat the SR-60 Does What It Does Not DoSR-60 Maintenance Installing/Using AccessoriesTransportation and Storage More on Informational LocatingMaintenance and Cleaning Locating Faulty ComponentsService and Repair Ridge Tool CompanyIcons and Symbols Icons and SymbolsGlossary -- Definitions Glossary -- Definitions Glossary -- Definitions Trouble Shooting Guide ProblemSpecifications Frequencies Table Default SettingsStandard Equipment Optional EquipmentManufacturers Frequency Table Ridgid Old Ridgid NewNew RycoRidge Tool Company