10. Storage

Aged fuel is one of major causes of engine starting failure. Before storing the unit, empty the fuel tank and run the engine until it uses all the fuel left in the fuel line and the carburetor. Store the unit indoor taking necessary measures for rust prevention.

PSZ2450S

U

S

11. Disposal

When disposing your machine, fuel or oil for the machine, be sure to allow your local regulations.

12. Troubleshooting guide

Case 1. Starting failure

CHECK

 

PROBABLE CAUSES

 

ACTION

fuel tank

incorrect fuel

drain it and with correct fuel

fuel filter

fuel filter is clogged

clean

carburetor adjustment screw

out of normal range

adjust to normal range

sparking (no spark)

spark plug is fouled/wet

clean/dry

 

plug gap is incorrect

correct (GAP: 0.6 – 0.7 mm)

spark plug

disconnected

retighten

 

 

 

 

 

Case 2. Engine starts but does not keep running/Hard re-starting.

CHECK

 

PROBABLE CAUSES

 

ACTION

fuel tank

incorrect fuel or staled fuel

drain it and with correct fuel

carburetor adjustment screw

out of normal range

adjust to normal range

muffler,cylinder (exhaust port)

carbon is built-up

wipe away

air cleaner

clogged with dust

replace

cylinder fin, fan cover

clogged with dust

clean

When your unit seems to need further service, please consult with our service shop in your area.

US-17

Image 17
Contents PSZ2450S Contents Parts location SpecificationsManufactured Symbols on the machineEmission Control Working Condition For safe operationWorking Circumstance Working PlanMaintenance Using the ProductStarting the Engine If Someone ComesTransportation Kickback and Pinching Safety PrecautionsHandling Fuel For safe operation Set up Fuel and Chain Oil WarrantyFuel Gasoline RequirementsFor Your Engine LIFE, Avoid HOW to MIX Fuel Recommended Mixing Ratio Gasoline 50 OILFueling the Unit Chain OILOperation Adjusting Throttle Cable Adjusting OIL Flow RateAdjusting Idling Speed OP9 OP8Maintenance SAW Chain Replacement Plug is a Champion RZ7CMA8 MA6Tightening Torque Procedures to be Performed After Every 100 Hours of USEMuffler Spark Arrester MA12Storage Troubleshooting guideDisposal Case 1. Starting failureOwners Warranty Responsibilities Manufacturers Warranty CoverageWarranty Commencement Date What is CoveredWhat is not Covered Emission Warranty Parts ListHOW to File a Claim Where to GET Warranty Service