Makita UB1103, UB1102 dimensions Repair, Switch

Page 2

P 2/ 8

Repair

CAUTION: Repair the machine in accordance with “Instruction manual” or “Safety instructions”.

[1] NECESSARY REPAIRING TOOLS

Code No.

Description

Use for

 

 

 

1R370

Ring Terminal Setting Jig

connecting Ring terminals to Brush holder

 

 

 

1R063

Guide Bar for fitting Field

assembling Field to Motor housing complete

 

 

 

[2] LUBRICATION

It is not required to lubricate, because the product has no gear mechanism to be lubricated.

[3]DISASSEMBLY/ASSEMBLY

[3]-1. Switch

DISASSEMBLING

1.Switch can be disassembled without separating Fan housing complete section. See Fig. 1.

Fig. 1

1.Remove four 4x18 Tapping screws that secure Handle cover to Motor housing.

Handle cover

4.Remove Switch from Handle section of Motor housing complete.

Switch

2.Separate Handle cover, pulling toward Fan housing complete side (pulling toward the direction designated with arrow No.1.)

3.Disassemble Handle cover by broadening Handle cover (pulling its ends toward the direction designated with arrow No. 2). Now, Handle cover is removed.

Handle cover

Fan housingNo.1 complete

No.2

ASSEMBLING

Assemble Switch by reversing the disassembly procedure. Refer to Fig. 1. Note: When mounting Handle cover, be careful of the following.

Switch and Lead wire are not pinched with Handle cover. Refer to Fig. D-2and Fig. D-3.

There are no gaps between Handle cover and Fan housing complete.

Image 2
Contents Standard equipment SpecificationOptional accessories UB1102 UB1103Switch RepairFan Section Motor Section DISASSEMBLY/ASSEMBLY Assembling Wiring of Field lead wires Circuit diagramWiring diagram Fig. D-3 On the right in Fig. D-2