IMPORTANT SERVICE INSTRUCTIONS
These servicing instructions are for use by qualified personnel only. To reduce the risk of electric shock, do not perform any servicing other than that ontained in the Operating Instructions unless you are qualified to do so. Refer all servicing to qualified service personnel.
IMPORTANT SAFETY INSTRUCTIONS
The lightning flash with arrowhead symbol, within an equilateral triangle is intended to alert the user to the presence of uninsulated „dangerous voltage“ within the product’s enclosure that may be of sufficient
magnitude to constitute a risk of electric shock to persons

 

 

 

 

The exclamation point within an equilateral triangle is

 

 

 

 

intended to alert the user to the presence of important

 

 

 

 

1.

 

Read these instructions.

operating and maintance (servicing) instructions in

 

the literature accompanying the appliance.

2.

 

Keep these instructions.

 

 

3.

 

Heed all warnings.

 

4.

 

Follow all instructions.

 

5.

 

Do not use this apparatus near water.

 

6.

 

Clean only with a dry cloth.

 

7.

 

Do not block any ventilation openings. Install in accordance with the manufacturers instructions.

8.

 

Do not install near any heat sources such as radiators, heat registers, stoves, or other apparatus

 

 

(including amplifiers) that produce heat.

 

9.

 

Do not defeat the safety purpose of the polarized or grounding-type plug. A polarized plug has two blades

 

 

with one wider than the other. A grounding type plug has two blades and a third grounding prong. The wide

 

 

blade or the third prong are provided for your safety. If the provided plug does not fit into your outlet, consult an

 

 

electrican for replacement of the obsolete outlet.

 

10.

Protect the power cord from being walked on or pinched particularly at plugs, convenience receptacles,

 

 

and the point where they exit from the apparatus.

 

11.

Only use attachments/accessories specified by the manufacturer.

12.

Unplug this apparatus during lightning storms or when unused for long periods of time.

13.

Refer all servicing to qualified service personnel. Servicing is required when the apparatus has been

 

 

damaged in any way, such as power-supply cord or plug is damaged, liquid has been spilled or

 

 

objects have fallen into the apparatus, the apparatus has been exposed to rain or moisture, does not

 

 

operate normally, or has been dropped

 

14.

To completely disconnect mains power from this apparatus, the power supply cord must be

 

 

unplugged.

 

15.

Do not expose this apparatus to dripping or splashing and ensure that no objects filled with liquids, such as

 

 

vases, are placed on this apparatus.

 

16.

The mains plug of the power supply cord shall remain readily operable.

Caution: Do not exceed the marked rating of the Mains Output.

Example: If each additional unit is rated 3A, a maximum of 3 units can be connected for a total of 9A.

CAUTION:

1.Security regulations as stated in the EN 60065 (VDE 0860 / IEC 65) and the CSA E65 - 94 have to be obeyed when servicing the appliance

2.Use of a mains separator transformer is mandatory during maintenance while the appliance is opened, needs to be operated and is connected to the mains

3.Switch off the power before retrofitting any extensions, changing the mains voltage or the output voltage.

4.The minimum distance between parts carrying mains voltage and any accessible metal piece (metal enclosure), respectively between the mains poles has to be 3 mm and needs to be minded at all times. The minimum distance between parts carrying mains voltage and any switches or breakers that are not connected to the mains (secondary parts) has to be 6 mm and needs to be minded at all times.

5.Replacing special components that are marked in the circuit diagram using the security symbol (Note) is only permissible when using original parts.

6.Altering the circuitry without prior consent or advice is not legitimate.

7.Any work security regulations that are applicable at the location where the appliance is being serviced have to be strictly obeyed. This applies also to any regulations about the work place itself.

8.All instructions concerning the handling of MOS - circuits have to be observed.

NOTE:

SAFETY COMPONENT ( MUST BE REPLACED BY ORIGINAL PART )

3

Image 3
Contents OWNER‘S Manual Bedienungsanleitung Inhalt ContentsSafety Component Must be Replaced by Original Part Description Input ControlsMains Fuse Bedienungsanleitung Inhalt Wichtige Sicherheitshinweise Auspacken & Garantie BeschreibungBedienelemente Mains Fuse Technical Specifications M212 SpecificationsDIMENSIONS/ Abmessungen Blockdiagram USA

Madras M 212 specifications

The Dynacord Madras M 212 is a sophisticated and highly versatile two-way sound reinforcement system that exemplifies the best in professional audio engineering. This loudspeaker is designed to deliver exceptional sound quality for live sound applications, whether in concert halls, theaters, or corporate events. Its robust build and advanced technology make it a reliable choice for audio professionals.

One of the most prominent features of the Madras M 212 is its dual 12-inch low-frequency drivers, which provide deep, powerful bass response while maintaining clarity across a wide frequency range. The system is engineered with a coaxial 1.4-inch neodymium compression driver that ensures impeccable mid and high-frequency reproduction. This combination allows the loudspeaker to cover a vast sonic spectrum, producing articulate audio that is essential for various musical genres and spoken word performances.

The cabinet of the Dynacord Madras M 212 is constructed from high-quality, multi-ply birch plywood, providing durability and excellent acoustic properties. The cabinet design features a trapezoidal shape, which helps minimize sound distortion and allows for flexible placement and array configurations. Moreover, the M 212 is equipped with a rugged steel grille that protects the drivers while optimizing sound dispersion.

In terms of technological innovations, the Madras M 212 incorporates Dynacord’s advanced DSP (Digital Signal Processing) technology. This allows for precise tuning and optimization of the loudspeaker's sound characteristics, accommodating various environments and performance needs. With built-in equalization and dynamic control features, users can achieve an exceptional audio experience tailored to their specific requirements.

Additionally, the Madras M 212 features versatile rigging options and integrated handles for easy transport and setup. It is compatible with a range of mounting accessories, making it suitable for both permanent installations and touring applications. The combination of high-quality components and thoughtful engineering ensures that the M 212 operates efficiently and reliably, even under demanding conditions.

Overall, the Dynacord Madras M 212 stands out as a powerful, efficient, and flexible loudspeaker solution, making it an ideal choice for sound reinforcement professionals seeking to deliver outstanding audio experiences in diverse settings.