Problem: Temperatures do not match if units are placed next to each other. Solution: Each temperature sensor is manufactured to be accurate to within 1 degree plus or minus and under normal conditions; so two temperature sensors could be as much as 2 degrees different. However, the difference can be exaggerated further because the temperature sensors are designed for different working environments. The indoor sensor is less responsive to ambient air currents because of the shielding effect of the display's case. In addition, the case can act as a heat sink to absorb and store heat from external sources (i.e. handling of the case or radiant heat). In addition, the much greater range of the outdoor temperature sensor requires a different calibration curve than the indoor range. Error is usually greater at the extreme ends of a range, making it harder to compare different ranges with different curves. Under non-laboratory conditions, it is difficult to compensate for the above factors and obtain an accurate comparison.

20

Image 20
Contents WS-9117U Wireless 433 MHz Temperature Station Table of Contents Inventory of Contents Quick Setup Do not Press ANY Buttons for 15 MinutesPage Page Page Page Page Indoor Temperature Station II. Time Setting the Time Time LCD IV. Features Minimum and Maximum Temperatures Resetting the Minimum and Maximum TemperaturesAdding Additional Remote Temperature Sensors Optional Page Outdoor LCD Mounting Remote Temperature Sensor Temperature StationPage Troubleshooting SolutionPage Maintenance and Care Instructions Specifications Measuring Temperatures1.5 x 1 Damage occurring during shipment claims must Page FCC Disclaimer FCC ID OMO-01RX Receiver OMO-01TX sensor