Giant installation instructions To Check Valves, GP7122 Repair Instructions

Page 7

GP7122 REPAIR INSTRUCTIONS

NOTE: Always take time to lubricate all metal and non-metal parts with a light film of oil before reassembling. This step will help ensure proper fit, at the same time protecting the pump non-metal parts (elastomers) from cutting and scoring.

TO CHECK VALVES

1)Lossen and remove screws (58C) with a 24mm socket wrench.

4)Take out valve assemblies (52 & 51) using either tool (part #07704) or a stud bolt.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

58B

58A

57

 

 

 

 

 

 

2) Take plugs (58) out of valve

 

3) Remove the compression

casing (50) by tightening

 

spring (57) O-Ring

(58A)

screws (58C) against valve

 

and support ring (58B).

casing with two screws.

 

 

 

 

 

 

 

51C (Suction)

52C (Discharge)

5)Valve seats (51C and 52C) are pressed out of spacer pipe (51F) by hitting the valve plate (51D) with a socket extention.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

51E

51D

52C

51A

51B

 

 

 

 

 

 

 

 

 

 

6)Check surfaces of valve plate (51D), valve seat (51C or 52C), o-rings (51A), and support rings (51B). Replace worn parts.

7

Image 7
Contents Model GP7122 Important Operating Conditions Installation InstructionsSpecifications Model GP7122 Exploded View GP7122 Part Description QTY GP7122 Parts ListGP7122 Repair Kits GP7122 Torque SpecificationsGP7122 Repair Instructions To Check ValvesLoosen nuts 49A with a 24mm socket wrench To Check Seals38A 38C 38B To Disassemble Gear END To Assemble Valve CasingGP7122 Dimensions Inches Giant Industries Limited Warranty