Graco Inc 824-006, 824-007, 824-001, 2800 owner manual Operation, Pressure Relief Procedure

Page 5

Operation

Pressure Relief Procedure

WARNING

INJECTION HAZARD

The system pressure must be manually

relieved to prevent the system from spraying accidentally. To reduce the risk

of an injury from accidental spray from the gun, splashing fluid, or moving parts, follow the Pres- sure Relief Procedure whenever you:

Dare instructed to relieve the pressure,

Dstop spraying for more than 10 minutes,

Dcheck or service any of the system equipment,

Dor install or clean the spray nozzle.

Startup

Always use this start±up procedure to ensure that the unit is started safely and properly.

1. Check oil levels:

NOTE: All units are equipped with a low-oil sensor that shuts the engine off if the oil level falls below a certain level. If the unit stops unexpectedly, check both the oil and the fuel levels. Check the oil level each time the unit is refueled.

2. Check fuel level.

Pressure Relief Procedure

1.Engage the trigger safety latch.

2.Turn the sprayer off.

3.Remove the ignition cable from the spark plug.

4.Shut off the water supply.

5.Disengage the trigger safety latch and trigger the gun to relieve pressure, and then engage the trigger safety latch again.

6.If you suspect that the spray tip or hose is completely clogged, or that pressure has not been fully relieved after following the steps above: Disengage the trigger safety latch and trigger the gun to relieve pressure. Wrap a rag around the hose end coupling and VERY SLOWLY loosen the coupling to relieve pressure gradually, then loosen completely. Now clear the tip or hose.

WARNING

FIRE HAZARD

Do not refuel a hot engine. Refueling a hot engine could cause a fire. Use only fresh, clean regular or unleaded gaso- line. Close the fuel shutoff valve during refueling.

CAUTION

Never run the unit dry. Costly damage to the pump will result. Always be sure the water supply is completely turned on before operating.

3. Turn on the water supply.

824±001 5

Image 5 Contents
This manual contains important warnings and information HYDRA-CLEAN2000 Pressure Washers 824±006 Series a 824±007, Series aTable of Contents 824±001 Hazardous FluidsSet Up InstallationCheck for Shipping Damage Connect to Water SupplyOperation Pressure Relief ProcedureOperation Installing and Changing Spray Tips Trigger Safety LatchTrigger Safety Latch Shown Disengaged Figure Follow the Pressure Relief ProcedureInterval What to do Shutdown, Flushing and StorageProblem Cause Solution Troubleshooting10 824±001 Pressure Relief Procedure Warning on 804±544 Pump ServiceValves Pumping Section12 824±001 Servicing the V-Packings804±559 Pump Service 14 824±001 Technical Data AccessoriesWater Sandblasting Kit 800±120 Anti±freeze Flush Kit 802±32716 824±001 Model 824±006, Series aDescription Qty Models 824±006, Series a18 824±001 Model 824±007, Series aModels 824±007, Series a 20 824±001 Pump Assembly ± PartsKit Repair Kit Description Qty 801-472 Model 804±544804-033 804-034 824±001 Washer Screw Model 804±559Warranty SHERWIN±WILLIAMS Warranty Disclaimers