Excell Precision XR2750 operation manual Starting, Shutting Down, Screen is

Page 12

STARTING

Prior to starting, refer to your engine manual for proper starting procedures.

1. In a well ventilated outdoor area add fresh, high quality, unleaded gasoline with a pump octane rating of 86 or higher. Do not overfill. Wipe up spilled fuel before starting the engine. Refer to Engine Owners Manual for correct procedure.

2. Check engine oil level. See Engine Owners Manual for correct procedure.

3. Verify the filter

 

 

 

 

Filter Screen

 

screen is in

 

 

 

 

 

 

 

 

water inlet of

 

 

 

pump. NOTE:

 

 

 

Cone side

 

 

 

faces out.

 

 

 

4.Connect water source to pump inlet.

NOTE: Water source must provide a minimum of 5 gallons per minute at 20 PSI.

5.Connect high pressure hose to pump outlet.

High Pressure Hose

Water

Source

6.If applying a chemical or cleaning solution, see How To Apply Chemicals/Cleaning Solvents instructions in this section.

7.To reduce operator fatigue while maintaining a consistent distance from the cleaning surface assemble the 'Water Vroom" cleaning surface guide. See Assembly section for assembly instructions.

8.Turn water source on. NOTE: Failure to do so could cause damage to the pump.

9.Start engine. See Engine Owners Manual for correct procedure. NOTE: When engine rope is pulled, pressure starts building in the gun. If the engine does not start after two pulls, pull the gun trigger to relieve this pressure.

10.Depress trigger on gun to start water flow. NOTE: Stand on a stable surface and grip gun/spray wand firmly with both hands. Expect the gun to kick when triggered.

NOTE: If using the "Water Vroom" surface cleaning guide, quickly and effortlessly guide it across the flat surface being cleaned.

11.Release trigger to stop water flow.

12.Adjust spray for the task being performed by changing quick connect nozzle. See How To Use Spray Wand instructions in this section.

SHUTTING DOWN

1.After each use, if you have applied chemicals, place chemical hose into container of clean water and draw clean water through chemical injection system to rinse system thoroughly. NOTE: Failure to do so could cause damage to the pump.

2.Turn engine off. See Engine Owner’s Manual. NOTE: NEVER turn the water off with the engine running.

3.Turn water source off.

4.Pull trigger on spray gun to relieve any water pressure in hose or spray gun.

5.See Storage section in this manual for proper storage procedures.

A12338

12- ENG

Image 12
Contents Table of Contents Pressure WasherConsumer Safety Information Important Safety InstructionsRisk of Explosion or Fire Risk of Explosion or Fire Risk to BreathingRisk of Chemical Burn Risk to Fluid Injection Risk of Electrical ShockRisk of HOT Surfaces Risk of Unsafe Operation Risk of Injury from SprayCarton Contents Assembly InstructionsENG A12338 Engine Switch Enables and disables ignition system Operating InstructionsBasic Elements of a Pressure Washer Basic Elements of AN EnginePressure Adjustments Pressure Washer TerminologyTo USE Spray Wand Nozzle Color Red Yellow Green White BlackUses SurfacesHOW to Apply Chemicals and Cleaning Solvents Read and Understand ALL Warnings Before Starting UnitTo Apply chemicals Press chemical Starting Shutting DownScreen is Maintenance Nozzle CleaningHOW to Clean the Water Inlet Filter Engine PumpReconnect spark plug wire StorageEngine Pressure WasherTrouble Shooting Guide ProblemCausecorrection Problem Cause Correction ENG A12338 Warranty

XR2750 specifications

The Excell Precision XR2750 is a state-of-the-art digital parallax-free microscope designed for high-precision inspections in a variety of industrial applications. Uniting advanced optics with innovative features, the XR2750 is ideal for quality control, research, or any task requiring meticulous detail.

One of the key features of the XR2750 is its high-resolution imaging capability. With a robust 5-megapixel camera, users can capture crisp, detailed images and videos for analysis and documentation. The microscope boasts a magnification range from 10x to 500x, providing flexibility for various applications, whether observing large components or intricate microstructures. The parallax-free design ensures a true representation of the specimen, eliminating common visual distortions.

Another notable characteristic of the XR2750 is its user-friendly interface. The device is equipped with a touchscreen control panel that allows for easy navigation through settings and adjustments. Users can quickly switch between different viewing modes, making it simple to adapt the microscope for specific needs. Additionally, programmable features enable a personalized experience, allowing users to save common settings for future use.

The XR2750 incorporates advanced LED illumination, which can be adjusted for brightness and intensity. This feature ensures optimal lighting conditions regardless of the sample being analyzed. The adjustable optics include both bright field and dark field illumination options, providing versatility while handling various materials and surfaces.

In terms of technology, the Excell Precision XR2750 is designed with ergonomic considerations in mind. The adjustable stand and focus knobs promote a comfortable working posture, reducing strain during extended usage. Furthermore, the microscope’s lightweight construction makes it portable, facilitating inspections in diverse settings.

The XR2750 is also compatible with various software programs, enabling seamless integration into digital workflows. Features like image comparison and measurement tools enhance data analysis, making it easier for professionals to obtain reproducible results.

Overall, the Excell Precision XR2750 digital microscope stands out in the market due to its combination of high-resolution imaging, user-centric design, and advanced technological features. It is an essential tool for industries that require precision and accuracy in their inspection and quality control processes, reinforcing its status as a reliable choice for professionals worldwide.