ooking for a quality, constant voltage and low Limpedance two channel amplifier for your res- taurant, nightclub, retail store, school or house
of worship projects? The Crown® “Contractor Series” amplifiers are designed just for you.
CL Series amplifiers provide 2, 4 and 8 ohm options per channel for applications where high power, low impedance loads are the primary requirement.
All Contractor Series amplifiers feature Crown’s exclusive SST (System Solutions Topologies) expan- sion system. The SST expansion system makes it easy to tailor your amplifier to a specific application or to add future technology as it develops.
With an incredibly wide range of power and fea- ture/benefits, Contractor Series amplifiers give the professional sound contractor more options. Crown quality is available at the best dollar-per-watt ratio on the market.
For more details about the Crown Contractor Series, contact the Crown Technical Support Group at 800- 342-6939 or 574-294-8200. Also, visit the Crown Audio website at www.crownaudio.com.
Features
| • Low impedance compatibility for applications | loads, DC, general overheating, high-frequency |
| where high power, low impedance loads are | overloads and internal faults. |
| the primary requirement. | • Can be mounted in standard (19-inch (48.3- |
| |
| • Rear panel detented level controls allow for | cm)) rack, shallow (14-inch (35.56-cm)) rack, |
| accurate level settings and secure operation. | or stacked on top of each other. |
| • “Contractor-Correct” barrier strip output con- | • Accurate, uncolored sound with very low |
| nectors allow for quick and easy connection, | distortion for the best in music and voice repro- |
| regardless of the load. | duction. |
| • Active crossover with signal routing available | • Three-Year, No-Fault, Fully Transferable War- |
| with optional System Solution Topology mod- | ranty completely protects your investment and |
| ules. | guarantees its specifications. |
| • 5-Way Fault Indicator serves as a valuable | • Crown’s Profit Protection Plan guarantees |
| system troubleshooting aid by quickly alerting | quick, no-questions-asked replacement of your |
| covered Contractor Series amplifier should it |
| the user of potential problems. |
| fail at any time up to 6 months following date |
| • Advanced protection circuitry guards against: |
| of installation. |
| shorted outputs, open circuits, mismatched | |
Specifications
Note: All measurements apply to amplifiers in stereo mode with 8-ohm loads and an input sensitivity
of 26-dB gain, 1-kHz at rated power unless other otherwise specified. Specifications for units supplied outside the U.S.A. may vary slightly at different AC voltages and frequencies.
Power
Output Power: See power charts below.
Load Impedance:
AC Line Connector: Detachable 15A IEC connector with country-specific plug.
Performance
Frequency Response, 20 Hz to 20 kHz at 1 watt: ±0.1 dB (CL1, CL2) or ±0.25 dB (CL4).
Phase Response: ±15 degrees deviation from linear phase from 20 Hz to 20 kHz at 1 watt.
Signal to Noise Ratio, A-Weighted: Better than 105 dB (CL1, CL2) or 102 dB (CL4) below rated 1-kHz power.
Controls
Level: A detented rotary level control for each channel located on the rear panel.
Power: An on/off rocker switch located on the front panel.
Mode: A two-position switch located on the back panel which, when turned to “Stereo,” operates the amplifier as two independent channels. When “Bridge” is selected, the amplifier bridges the two output channels for twice the output voltage.
Safe with all types of loads.
2, 4 and 8 ohm Stereo. 4, 8 and 16 ohm Bridge.
Voltage Gain, 1 kHz, 1.4V sensitivity:
30.5dB (CL1), 32.1 dB (CL2), or 34 dB (CL4) into 8 ohms.
AC Line Requirements:
Note: North American units are 60 Hz only. All other models are 50/60 Hz. Voltages are ±10%.
AC Line Current:
100V: 7.6A (CL1), 11.4A (CL2), or 8.5A (CL4).
120V: 6.3A (CL1), 9.5A (CL2), or 7.1A (CL4).
230-240V: 3.5A (CL1), 5.0A (CL2), or 3.7A (CL4).
CL1 | *1 kHz |
Power |
2 ohm Stereo (per channel) | 560W |
4 ohm Stereo (per channel) | 450W |
8 ohm Stereo (per channel) | 275W |
4 ohm Bridge-Mono | 1,100W |
8 ohm Bridge-Mono | 900W |
*1 kHz Power: refers to maximum average power in watts at 1 kHz with 0.5% THD.
Total Harmonic Distortion (THD), 1 kHz at rated power: 0.5% or less true THD from 20 Hz to 20 kHz.
Intermodulation Distortion (60 Hz and 7 kHz at 4:1): Less than 0.1% (CL1, CL2) or 0.5% (CL4) at rated power to 30 dB below rated power at 8 ohms.
Damping Factor (8 ohm): Better than 400 (CL1, CL2) or 700 (CL4) from 10 Hz to 400 Hz.
Crosstalk, 20 Hz to 20 kHz: Better than 50 dB below rated power.
Common Mode Rejection (CMR): Better than 40 dB
from 20 Hz to 1 kHz.
DC Output Offset (shorted input): < ±10 mV.
CL2 | *1 kHz |
Power |
2 ohm Stereo (per channel) | 975W |
4 ohm Stereo (per channel) | 660W |
8 ohm Stereo (per channel) | 400W |
4 ohm Bridge-Mono | 1,950W |
8 ohm Bridge-Mono | 1,320W |
*1 kHz Power: refers to maximum average power in watts at 1 kHz with 0.5% THD.
Indicators
Signal: A green indicator for each channel which flashes when a very low-level signal (> –40 dBm) is present at input. May be used for troubleshooting cable runs.
Clip: A red indicator for each channel which turns on when distortion becomes audible in the amplifier output.
Fault: A red indicator for each channel which indi- cates amplifier has muted output. Normally off. Status may be monitored remotely by plugging into back- panel RJ11 Fault jack.
Power: A blue indicator that turns on when the ampli- fier has been turned on and has power.
CL4 | *1 kHz |
Power |
2 ohm Stereo (per channel) | 1,400W** |
4 ohm Stereo (per channel) | 1,200W |
8 ohm Stereo (per channel) | 600W |
4 ohm Bridge-Mono | 2,800W** |
8 ohm Bridge-Mono | 2,400W |
*1 kHz Power: refers to maximum average power in watts at 1 kHz with 0.5% THD.
**≥ 200-V line voltage provides 1,800W (2 ohm stereo) and 3,600W (4 ohm bridge-mono)