Crown Audio CE2000TX operation manual Specifications, 120 VAC, 60 Hz Units, Bridge mono mode

Page 23

CE2000TX Power Amplifier

8 Specifications

Minimum Guaranteed Power

120 VAC, 60 Hz Units, Stereo mode, per channel, both channels driven

1 kHz with < 0.5% THD

 

 

Dual, 4 ohms (per ch.)

660 W

 

Dual, 8 ohms (per ch.)

400W

 

 

 

 

120 VAC, 60 Hz Units, Bridge mono mode

 

 

 

 

 

1 kHz with 0.1% THD

 

 

Bridge mono, 8 ohms

1,320 W

 

 

 

 

Performance

 

 

 

 

 

Frequency Response (at 1 watt, 20Hz - 25 kHz)

< ±0.2 dB

 

 

 

 

Phase Response (at 1 watt, 20Hz - 20 kHz)

< ±15°

 

 

 

 

Signal to Noise Ratio below rated power (20 Hz to 20 kHz)

> 100 dB

 

 

 

 

Total Harmonic Distortion (THD) at rated power, from 20 Hz to 20 kHz

0.5%

 

 

 

 

Intermodulation Distortion (IMD) 60 Hz and 7 kHz at 4:1,

 

 

from 163 milliwatts to full bandwidth power

< 0.1%

 

 

 

 

Damping Factor: 10 Hz to 400 Hz

> 400

 

 

 

 

Crosstalk (below rated power, 20 Hz to 20 kHz)

> 55 dB

 

 

 

 

Common Mode Rejection (CMR) (20 Hz to 1 kHz)

> 70 dB

 

 

 

 

DC Output Offset (Shorted input)

±10 mV

 

 

 

 

Input Impedance nominally balanced, nominally unbalanced

20 k ohms, 10 k ohms

 

 

 

 

Load Impedance (Note: Safe with all types of loads)

 

 

Stereo

4 and 8 ohms

 

Bridge Mono

8 ohms

 

 

 

 

Voltage Gain (at maximum level setting)

 

 

26dB sensitivitiy

26 dB

 

1.4V sensitivity

32.1 dB

 

 

 

 

Required AC Mains (configured country-specific)

50/60 Hz, 100 - 240 VAC

 

 

 

 

Power Draw at Idle

90 watts

 

 

 

 

Cooling

Proportional speed fan

 

 

 

 

Dimensions: Width, Height, Depth

EIA Standard 19 in. (48.3 cm) x 5.25 in. (13.34 cm) x 12.25 in. (31.11 cm)

 

 

 

 

Net Weight, Shipping Weight

40.3 lb (18.28 kg), 46.4 lb (20.98 kg)

 

 

 

 

Operation Manual

page 23

Image 23
Contents Some models may be exported under the name Amcron CE 2000TXImportantes Instructions de Sécurité Important Safety InstructionsCompetent Body’s Name and Address Safety StandardCrown International, Inc TCF Technical Certificate No C975CRI1.ABSTable of Contents Accurate, undistorted sound How to Use This ManualFeatures WelcomeYou may also stack amps without using a cabinet SetupUnpack Your Amplifier Install Your Amplifier Balanced Input Connector Wiring Choose Input Wire and ConnectorsNeutrik Speakon Connector Choose Output Wire and Con- nectorsSee the next page for Bridge-Mono wiring Wire Your System Stereo ModeHow to Parallel the Inputs in Stereo Mode 11 Typical System Wiring, Bridge Mono Mode Bridge-Mono ModeCE2000TX Power Amplifier CE2000TX Power Amplifier CE2000TX Power Amplifier Operation Input Sensitivity SwitchStartup Procedure PrecautionsControls, Indicators and Connectors Advanced Features Options SST-4632 SST-4622SST-3632 Location of Fault Jack Fault MonitoringTamper-Resistant Hole Plugs Options Alternate Output ConnectorsOptional 0.775V Input Sensitivity Setting Principles of Operation Power LED is driven from the low-voltage supply+ HI-VOLTAGE Bootstrap Condition Power indicator is off Troubleshooting120 VAC, 60 Hz Units, Bridge mono mode SpecificationsService United States & Canada WarrantyWorldwide Except USA & Canada Crown Audio Factory Service Information