This centrifugal pump requires little or no service other than reasonable care. Occasionally, however, a shaft seal becomes damaged and must be replaced.
E.Protect Motor Against Heat
1.Shade the motor from the sun.
2.Provide ample cross ventilation.
F.Protect Motor Against Dirt
1.Keep motor, motor vents, and surrounding area clean.
2.Avoid sweeping or stirring up dust near the motor while it’s running.
3.Avoid storing (or spilling) pool chemicals near the motor.
G.Protect Motor Against Moisture
1.Provide protection from rain, snow, lawn sprinklers, etc.
2.Locate motor on a slight elevation so water will not run or puddle nearby.
3.Avoid spilling or dripping liquid chemicals on or near motor.
4.Avoid splashing water near the motor.
5.Do not wrap motor with plastic or other
(Exception: The motor may be covered during a storm, when hosing, winter storage, etc.; never when motor is running or expected to be running).
NOTE
When replacing motor, be certain that motor support (part number 39201300) is correctly turned and positioned to support type of motor being installed.
CAUTION
In mild climate area - when temporary freezing conditions may occur, run your filtering equipment all night to prevent freezing.
SECTION III. TROUBLESHOOTING
System Problem | Cause | Remedy |
|
|
|
Failure to Pump | 1. Pump will not prime - too much air. |
Check suction piping and valve glands on any suction gate valves. Secure lid on pump strainer pot and make sure lid gasket is in place. Check water level to make sure skimmer is not drawing air.
2.Pump will not prime - too little water. Make sure suction lines, pump strainer, and pump volute are full of water. Make sure valve on suction line is working and open (some systems do not have valves). Check water level to make sure water is available through skimmer.
3. | Pump strainer clogged. | Clean pump strainer pot. |
4. | Pump strainer gasket defective. | Replace gasket. |
Reduced Capacity and/or Head 1. Air pockets or leaks in suction line.
Check suction piping and valve glands on any suction gate valves. Secure lid on pump strainer pot and make sure lid gasket is in place. Check water level to make sure skimmer is not drawing air.
2. | Clogged impeller. | Remove, clean and adjust. |
3. | Pump strainer clogged. | Clean suction trap. |
|
|
|
P/N 99330000 | 4 | Rev. |