KNOW YOUR GENERATOR

Read this owner’s manual and safety rules before operating your generator.

Compare the illustrations with your generator to familiarize yourself with the locations of various controls and adjustments. Save this manual for future reference.

Fuel Tank

Electric Start Button

Recoil Starter

Battery Tray

Location

120 Volt AC, 30 Amp

Receptacle

12 Volt DC, 10 Amp Receptacle — Used with battery charge cables to charge a 12 Volt battery.

120 Volt AC, 20 Amp Receptacles — May be used to supply electrical power for the operation of 120 Volt AC, single phase, 60 Hz electrical lighting, appliance, tool and motor loads.

120 Volt AC, 30 Amp Receptacle — May be used to supply electrical power for the operation of 120 Volt AC, 30 Amp, single phase, 60 Hz electrical lighting, appliance, tool and motor loads.

120/240 Volt AC, 30 Amp Receptacle — May be used to supply electrical power for the operation of 120 and/or 240 Volt AC, 30 Amp, single phase, 60 Hz electrical lighting, appliance, tool and motor loads.

Battery Tray Location Pre-tapped and installed screws are found here for the battery tray

Circuit Breakers (AC)

120/240 Volt AC

30 Amp Receptacle

120 Volt AC, 20 Amp

Receptacle

Idle Control Switch

12 Volt DC, 10 Amp

Receptacle

Grounding Wing Nut

Circuit Breakers (AC) — Each receptacle is provided with a "push to reset" circuit breaker to protect the generator against electrical overload.

Electric Start Button — Press to start unit.

Fuel Tank — Capacity of seven U.S. gallons of unleaded fuel.

Grounding Wing Nut— Use this connection to properly ground the generator.

Idle Control Switch — The idle control runs the engine at normal (high) speeds when there is a load present and runs the engine at idle (low) speeds when a load is not present.

Recoil Starter — Used as an alternate method of starting the unit.

4

Image 4
Contents 5500EXL Safety Rules Equipment DescriptionGrounding Generator Never operate this generatorKnow Your Generator Electric Start Button Press to start unitInstalling Tray and Battery Carton ContentsRemove Generator from Carton Before Starting the Engine Add OilAdd Fuel To fill your engine with oilOperating Generator Starting the EngineTo add fuel For electric startOFF when starting and stopping the engine Cold Weather OperationApplying Electrical Loads Stopping the EngineCharging a Battery To recharge 12 Volt batteries, proceed as followsCord SETS/RECEPTACLES Volt AC, 20 Amp Receptacles120/240 Volt AC, 30 Amp Locking Receptacle Volt AC, 30 Amp Locking ReceptacleDON’T Overload the Generator Wattage Reference GuideSERVICE/ADJUSTMENTS Storage General Maintenance RecommendationsSpecifications Troubleshooting Schematic Diagram Wiring Diagram Exploded View Qty Description Parts ListParts Not Illustrated Control Panel Exploded View & Parts List Circuit BREAKER, 20AGenerac Portable Products 5500EXL Extended Life Generator Limited Warranty Consumer Commercial