To Start The Generator:
1.Turn the Fuel Valve (31) to its vertical “OPEN” position.
(See Figure F.)
2.Move the Engine’s Choke all the way to the left to its “START” position.
(See Figure F.)
3.Turn the Engine’s “ON/OFF” switch to its “ON” position. (See Figure G.)
4.Insert the Ignition Key into the Igni- tion Switch (45), and turn the Ignition Key to the right to start the Engine.
(See Figure H.)
5.Allow the Engine to run for several seconds, then move the Engine’s Choke all the way to the left to its “RUN” position. (See Figure F.)
NOTE: DO NOT ATTEMPT TO ADJUST THE ENGINE’S THROTTLE! This engine uses a governor device to automatically control the engine’s speed. If the throttle is adjusted, it may result in decreased ef- ficiency and/or damage to the unit.
CHOKE
FUEL VALVE (31)
Hidden from view
FIGURE F
ON/OFF
Switch
FIGURE G
OVERLOAD BREAKERS
120/240 V
TWISTLOCK OUTLETGROUNDING POINT
(42)
(44)
120V DUAL OUTLET | IGNITION SWITCH | |
(43) | ||
(45) | ||
|
FIGURE H