ACDelco AC-G0003 instruction manual Checking the Oil Changing/Adding Oil

Page 20

Figure 11 - Checking the Oil

Changing/Adding Oil

The oil level in this generator should be checked before each use. (See Figure 10.) When the oil level is low, add oil until the level is sufficient to operate this generator.

The oil capacity for this ACDelco Model AC-G0003 5500 Surge Watts / 5000 Running Watts Portable Generator engine is 1.2 Qt. (38 fluid oz.) (1.13 L).

To drain the oil from this generator:

It is necessary to drain the oil from the crankcase only if it has become contaminated with water and/or dirt.

1.Place a bucket underneath this generator to catch oil as it drains.

2.Using a 10 mm hex wrench, unscrew the oil drain plug located on the crankcase underneath the oil filler/dipstick cap as illustrated in Figure 12.

3.Allow all the oil to drain from this generator.

4.Replace the oil drain plug and tighten with a 10 mm hex wrench.

NOTE: Never dispose of used motor oil in the trash, down a drain or on the ground. Put oil in a sealed container and contact your local recycling center or auto garage to arrange oil disposal.

To add oil to the engine crankcase:

1.Confirm that this generator is on a level surface.

2.Unscrew the oil filler/dipstick cap from the engine as illustrated in Figure 11 above.

3.Using a funnel, add high detergent motor oil to fill the engine crankcase to the correct quantity. SAE10W-30 oil is recommended for general use. When the engine crankcase is full, the oil level should reach the lower lip of the oil filling opening as shown in Figure 13.

Model AC-G0003 Oil Capacity (Qt/fluid oz./L)

1.2 / 38 / 1.13

Model AC-G0003 Oil Type Recommended

High Detergent Motor Oil, SAE10W-30

Model AC-G0003 5500 Surge Watts / 5000 Running Watts Portable Generator

20

Image 20
Contents Questions? Problems? Contact Buffalo Tools Portable GeneratorFeatures Table of Contents Recognize Safety SYMBOLS, Words and Labels Important Safety Instructions Legal RequirementsPage Page Page Package Contents Generator Components Add Oil Using this Generator for the First-TimePreparing the Generator for USE Add Gasoline Verify Oil Level Ground the GeneratorSubsequent Use of this Generator Starting the Generator Verify Gas LevelAC Usage Using the GeneratorComponents chart to find the location of the Choke Lever Estimated wattage requirements for common electrical devices Do not connect 50Hz or 3-phase loads to this generator Maximum Extension Cord Lengths by Power RequirementStopping the Generator DC UsageMAINTENANCE/CARE Recommended Maintenance ScheduleCleaning the Generator Checking the Oil LevelChecking the Oil Changing/Adding Oil Air Filter Maintenance Fuel Filter Cup CleaningModel AC-G0003 Spark Plug Gap in/mm 028-0.031/0.7-0.8 Spark Plug MaintenanceModel AC-G0003 Spark Plug Type STORAGE/TRANSPORT Procedures Emptying the Fuel TankDo not store gasoline for more than 3 months Storage TimeTroubleshooting Specifications Exploded View and Parts List Parts List Part Qty DescriptionPage Page Warranty RegistrationPage Model # AC-G0003 Watt Generator Portability KIT InstallationStep
Related manuals