Intel SIU520 SS7 manual Table of Contents

Page 2

Building Fault-tolerant SS7 Systems Using the Intel® NetStructure™ SIU520 SS7 Signaling Gateway Application Note

Table of Contents

Abstract

1

 

 

Introduction

1

 

 

Overview of SIU Operation

2

Circuit-switched API Operation

2

Transaction-based API Operation

3

Management Interface

3

 

 

Potential Points of Failure

3

Failure of SS7 Links

4

Failure of Routes

5

Failure of Power Supply

6

Failure of Signaling Interface Unit

6

Routing Architectures of a Dual-resilient SIU System

7

Dual SIU architecture for Circuit-switched Applications

10

Dual SIU architecture for Transaction-based Applications

13

Failure of IP Subnetwork

15

Failure of Application

15

Configuring a Dual SIU Pair

17

Hardware Requirements

17

System Configuration

18

Changes to the config.txt Parameter File

18

Configuring the Inter-SIU Link

18

Routing Configuration

19

Circuit Group Configuration

19

Example Configuration

19

 

 

Run-time Operations of a Dual-resilient SIU System

20

Connecting a Host to Two SIUs

20

Communicating with Both SIUA and SIUB

21

Transferring Control of a Circuit Group between SIUs

21

Activating and Deactivating Circuit Groups

21

System Initialization

21

Failure Detection

21

Transferring the Circuit Group

22

Re-synchronization of the Circuit Sate Information

22

Recovery of the Failed Unit

23

Transferring Control Back

23

Circuit Group Conflict

23

 

 

Appendix A: Frequently Asked Questions

24

 

 

Appendix B: For More Information

24

 

 

Appendix C: Abbreviations

24

 

 

Image 2
Contents Intel Communications Application NoteTable of Contents Table of Figures Abstract Circuit-switched API Operation SIUTransaction-based API Operation Management InterfaceFailure of SS7 Links SIU Connected to Adjacent Node with Two Links in Link SetFailure of Routes LinkFailure of Power Supply Failure of Signaling Interface UnitConnection to a Single Adjacent Signaling Point Routing Architectures of a Dual-resilient SIU SystemConnection to an Adjacent Mated STP Pair Compares the advantages and disadvantages of these methods Dual SIU Architecture for Circuit-Switched Applications SS7MTP1-3 Circuit Group Active Inactive MTP1-3 Dual SIU Architecture for Transaction-based Applications Siua SiubSS7 Failure of IP Subnetwork Failure of ApplicationHost SIU520Hardware Requirements Inter-SIU Link over Crossed E-1/T-1 CableConfiguring the Inter-SIU Link System ConfigurationChanges to the config.txt Parameter File Example Configuration Routing ConfigurationCircuit Group Configuration For Siub Connecting a Host to Two SIUsFor Siua GCTgetinstance Communicating with Both Siua and SiubGCTsetinstance Transferring Control of a Circuit Group between SIUsTransferring the Circuit Group Re-synchronization of Circuit State InformationCircuit Group Conflict Recovery of the Failed UnitTransferring Control Back What happens if an inter-SIU SS7 link fails? How can I tell if an SIU fails?If an SIU fails do I need to take any action? What happens if the Ethernet interfaces fail on an SIU?Route Ten Parsippany, NJ Phone

SIU520 SS7 specifications

The Intel SIU520 SS7 is a significant advancement in the realm of telecommunications, specifically designed for seamless signaling in a wide array of telecommunication infrastructures. As a part of Intel's pioneering suite of products, the SIU520 plays a critical role in managing signaling for telephony systems that require efficient handling of SS7 protocols.

One of the main features of the SIU520 is its support for the SS7 signaling protocol, which is pivotal for the establishment and management of telephone calls over traditional circuit-switched networks. With its robust design, the SIU520 ensures reliability in signaling, contributing to the reduction of call set-up times and the minimization of errors, thus enhancing the overall quality of communication services.

The SIU520 incorporates advanced technologies such as high-speed data processing capabilities, allowing it to handle multiple signaling messages concurrently. This is particularly important in environments with high call volumes, where efficient processing can significantly affect the performance of telecommunication services. Furthermore, the architecture of the SIU520 is designed for scalability, enabling easy integration into existing infrastructures while accommodating future expansions as demand increases.

Another characteristic that sets the SIU520 apart is its support for various signaling types beyond standard SS7, including ISDN and SIP. This makes it a versatile tool for service providers aiming to offer diverse services, such as voice, video, and data communications. The SIU520 is also designed with a focus on interoperability, which ensures that it can effectively communicate with equipment from different manufacturers, thus providing flexibility in deployment.

In terms of security features, the SIU520 is architected to withstand common threats in the communication landscape. It employs encryption and authentication protocols to safeguard signaling traffic, ensuring that sensitive information remains protected during transmission.

In summary, the Intel SIU520 SS7 represents a robust and flexible signaling solution crucial for modern telecommunications. With its support for multiple protocols, high processing speeds, scalability, and secure communication capabilities, it stands as a testament to Intel's commitment to advancing telecommunication technologies and enhancing the efficiency and reliability of communication networks worldwide.