Intel 6000 quick start Install additional Power supplies, Install Network modules

Page 4

Install additional

4 power supplies

If you purchased an additional power sup- ply, place it in one of the empty power supply bays at the top of the chassis.

1Loosen and remove the capture panel screws on the face plate of the power supply bay.

2Push the power supply into the power supply bay until the capture panel screws engage the chassis.

3Tighten the capture panel screws.

Install the

5 network modules

You can install network modules, such as the 1000Base-SX, 1000BaseLX / 1000BaseSX and 10/100Base-TX, in any available slot on the chassis

1Remove the filler panels from any slots (1-4) that will hold network modules.

2Push the module back until it connects with the backplane connector, and the capture panel screws engage the chassis.

3Tighten both capture panel screws simultaneously.

4Leave the filler panels in any unused slots. Doing so keeps dust out of the switch and helps maintain proper air- flow.

Capture Panel

Screws

Gigabit

Ethernet

Module

2

Image 4
Contents Intel NetStructure Switch First Edition May Set up the switch Install the carrier Tray moduleInstall the Control Processor module Quick StartInstall additional Power supplies Install Network modulesPlug in the switch Connect to devicesManagement Options Configure Manage the switchOption 1 Local Management Option 2 Intel Device View WebOption 3 Web Device Manager