Removing and replacing a FRU
1130 CPU
For access, remove these FRUs in order:
v“1010 Battery pack” on page 44
v“1100 Thermal module slot cover” on page 52
v“1110 Fan” on page 53
v“1120 Thermal module” on page 54
Attention: CPU is extremely sensitive. When you service the CPU, avoid any kind of rough handling.
Rotate the head of the screw in the direction shown by arrow | to release the | ||||||||||
lock; then remove the CPU in the direction shown by arrow | . | ||||||||||
|
|
|
|
|
|
|
|
|
| ||
|
|
|
|
|
|
|
|
|
| ||
|
|
|
|
|
| 1 |
|
|
|
| |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
a |
b
2
When installing: Place the CPU on the CPU socket | , and then rotate the head | |
of the screw in the direction shown by arrow | to secure the | |
CPU. |
|
|
56MT 8922