MAINTENANCE

Lamp

HIGH VOLTAGE

HIGH TEMPERATURE

HIGH PRESSURE

Contact your dealer before replacing the lamp.

For the optional lamp, see the item “Option Parts” of the Table 12.

Before replacing the lamp, switch power OFF, remove the power cord from the power outlet, and wait approximately 45 minutes until the lamp has cooled. The lamp may explode if handled at high temperatures.

ENGLISH

WARNING A mercury lamp used in this LCD projector is made of glass and has high internal pressure. The mercury lamp can burst with a big noise due to deterioration

resulting from a shock, crack and passage of time, and can end its service life in unlit condition. Lamps also have a considerably different service life and can sometimes end up in burst or turn to unlit condition soon after use. Furthermore, when the lamp is blown up, glass fragments can get scattered around the lamp house and some gas containing mercury inside the lamp can leak out of the projector’s air vent.

Handle the lamp with utmost care as it can burst during use if subjected to a shock or impact or if scratched or cracked.

Probability for the burst will increase if the lamp is used for extended period of time or used exceeding the period of replacement. You are advised to follow instructions for lamp replacement as soon as they are given (Refer to Table 9 of Page 20, Table 10 of Page 21). Avoid any reuse of an old lamp (used lamp) since such reuse can result in burst.

In case the lamp gets blown up in a short period of time after use, some electrical failures or troubles other than the lamp itself may be suspected as causes. Under such circumstances, consult the store where you purchased it or a service company.

Should the lamp burst (accompanied by a big bursting noise), perform ventilation sufficiently, and exercise maximum caution not to inhale any gas out of the projector’s air vent or not to let it enter your eyes or mouth.

Should the lamp burst (accompanied by a big bursting noise), make absolutely sure to unplug the power cord from the outlet and ask the store where you bought the lamp for immediate replacement. You should not engage in cleanup or replacement of the lamp by yourself since scattered glass fragments can damage the inside of projector or can result in personal injury when you handle it.

When you dispose of any used lamps, be sure to observe and follow local ordinances and regulations of the area or district where they are subjected to disposal. Generally speaking, the lamps are treated similarly as glasses and bottles in most cases, but there are areas or districts where lamps are classified as a separate collection, and so be sure to use caution.

Never use the lamp in a state where the lamp cover is removed.

Lamp Life

Projector lamps have a finite life. The image will become darker, and hues will become weaker, after a lamp has been used for a long period of time.

Replace the lamp if the LAMP indicator is red, or the CHANGE THE LAMP message appears when the projector is switched ON. See Table 9 of P.20 and Table 10 of P.21.

NOTE The LAMP indicator is also red when the lamp unit reaches high temperature. Before replacing the lamp, switch power OFF, wait approximately 20 minutes, and switch power ON again. If the LAMP indicator is still red, replace the lamp.

ENGLISH-17

Downloaded from www.Manualslib.com manuals search engine

Image 18
Contents CP-X990W/CP-X995W Contents Features Contents of packageBefore USE Before USE Part NamesAuto Button Reset ButtonOther people. The laser beam can cause vision problems RGB Button Mouse / Right ButtonLoading the Batteries Angle Adjustment InstallationInstallation of the Projector and Screen Installation ReferenceCabling InstallationCabling Function Terminal CablePower Connection Example of System SetupPlug & Play Operations Power onPower OFF StandbyOperations Basic OperationBasic Operation Description Normal menu Single menu Select Mode of P.IN P. Display Press the PinP buttonSet / Clear Keystone Mode Press the Keystone button Menu Display Start/Stop Press the Menu buttonSetup Menu Setup MenuRGB Input MenuInput Menu Description Video NRMyScreen Image MenuImage Menu Description MirrorSelect Menu Background Color Select with Options MenuOptions Menu Operation Start/Stop PressSet / Crear Whisper Mode Press No Signal MenuNo Signal Menu Operation Start/Stop PressMaintenance LampLamp Life Maintenance Resetting the Lamp TimerReplacing the Lamp Other Maintenance Air FiltersOSD Message TroubleshootingMessage Contents OSD MessageIndicators Message TroubleshootingIndicators Message IndicatorSymptom Possible cause Remedy SymptomSymptom 11,15Specifications SpecificationsWarranty and AFTER-SERVICE Dimension Diagram Signal Connector Pin AssignmentTechnical Example of computer signal Resolution FH kHz FV Hz Rating Signal mode DisplayTechnical Initial set signals USB Mouse Connection to the Mouse ControlPS/2, ADB or Serial Mouse PS/2 MouseADB Mouse Serial MouseRS-232C communication Communications settingCommand data ProtocolUsing the projector default settings Reset Command Requesting projector status Get commandChanging the projector settings Set command Increasing the projector setting value Increment commandCRC Be EF BA D2 Be EF FD D3 Be EF Ntsc PAL RGB Be EF Regulatory Notices FCC Statement WarningFor the Customers in Canada Pour les utilisateurs au Canada Hitachi Business Systems Nordic Hitachi Europe GmbHHitachi Sales Europe GmbH Hitachi France